background image

 

 

 

I

NSTRUCTION MANUAL

 

V

OLTAGE REGULATOR

 

MAXBEC2D EX 

 

 

 

 

 

Released by JETI model s.r.o 

8.2.2010 

Summary of Contents for MAXBEC2D EX

Page 1: ...INSTRUCTION MANUAL VOLTAGE REGULATOR MAXBEC2D EX Released by JETI model s r o 8 2 2010...

Page 2: ...D to a DUPLEX receiver 6 3 2 3 Connecting MAXBEC2D to a DUPLEX Expander 6 4 MENU NAVIGATION 7 4 1 ACTUAL VALUE 7 4 2 MIN MAX MINIMUM AND MAXIMUM VALUES 7 4 3 SETTING CONFIGURATION OPTIONS 7 4 4 ALARMS...

Page 3: ...and the MAXBEC2D features two LED s indicating the connection state of the the connected packs The MAXBEC2D can be monitored and configured via the JETIBOX either by direct connection or wirelessly us...

Page 4: ...t B Output Magnetic switch Ext JR connector for Duplex JETIBOX Pins for jumper selection of output voltage LED Batt A LED Batt B LED Indicator for input voltage 2 2 Magnetic switch The magnetic switch...

Page 5: ...cipated load to the MPX output connector of the MAXBEC2D or use the JETI MPX 3xJR cable available separately The Duplex EPC receivers such as the R6 EPC R8 EPC R12 R14 and R18 are already fitted with...

Page 6: ...XBEC2D DUPLEX Receiver EXT SERVOS DUPLEX Sender JETIBOX MAXBEC2D EXT UOUT Batt A Batt B POWER OUTPUT from MAXBEC2D MAGNETIC SWITCH 3 2 3 Connecting MAXBEC2D to a DUPLEX Expander Connect the MAXBEC2D t...

Page 7: ...Data menu option The values are automatically erased when the unit is switched on and the input voltages exceed those specified in the Trigger Level menu option Accum A MIN MAX Shows the minimum and m...

Page 8: ...switch plate and on the MAXBEC2D should become active This is also the voltage at which the first green LED should deactivate Step Value The voltage value of each step between the green input voltage...

Page 9: ...tting See section SETTING Configuration Options and change to your desired value This can be done in steps of 0 1V independently of the position of the short circuit jumper plug The factory default se...

Page 10: ...until the unit is switched off and the battery is disconnected Always follow the same procedure when switching on off To switch on first connect the batteries and then use the magnetic switch to acti...

Page 11: ...W Operating Temperature 10 C a 130 C Weight 85 g Dimensions 100 x 29 x 16 mm Table showing the dependency between input voltage output voltage and continuous current capability Number of power supply...

Page 12: ...INSTRUCTION MANUAL 12 12 Menu Diagram of MAXBEC2D...

Reviews: