Serial Number: 1203
25
1 -
Cabin
Ignition off
Main switch on, check fuel level, check instruments
Main switch off
Check range of movement of all controls, condition of safety harnesses
Remove loose objects from cabin, check canopy – cleanliness
Check rescue system – must be locked to prevent inadvertent activation
2 -
Fuselage, wings and tail surfaces
Check surface condition, leading edges
Check Pitot tube
3 -
Control surfaces, wing flaps
Range of movement and free play of all control surfaces
4 -
Landing Gear
Check wheels for free rotation, tire inflation (2,3 bar), attachment to airframe, check
brakes, attachment of wheel fairings, check tire slipping on rims
5 -
Engine, propeller, fuel system
Check fuel level and cleanliness, check propeller and attachment to engine
Check oil level (according to engine manufacturer’s manual), check coolant
Check engine cowling
Check tightness of fuels hoses, tank caps, fuel filters
Check fuel filter for impurities and water
5.2
Refueling
Rotax 912 engines are designed for automotive lead-free gasoline (BA95 Natural).
Temporary limited use of AVGAS is possible. See Rotax 912 UL, Rotax 912 ULS
Operating manual for more details.
The aircraft has two fuel tanks, capacity 50L each.
There are two methods of refueling LEGEND aircraft.
1)
Refueling from fuel station (dispenser)
Fuel station must be certified for aircraft refueling.
Always neutralize electric potentials of aircraft and station.
LEGEND aircraft has two grounding points for this purpose. One of them is copper
grounding strip at landing gear leg. The other is exhaust manifold, which is better suited
for attachment of grounding clip of refueling station.
Do not handle fuel tank before
completing the grounding.
Open fuel cap and insert filling nozzle into tank. It is not
necessary to use strainer, as certified refueling stations always include it.