background image

無線資訊傳設備的製造廠商應確保頻

穩定性,如依製造廠商使用手冊上所述正常操作,發射的信號應維持

於操作頻帶中。

Taiwan MPE Warning - Aerohive AP122

電磁波曝露量

MPE

標準值

(MPE) 1mW/cm2

,送測產品實值為

0.196868 mW/cm2

NCC

 

Statement - Aerohive AP122

1.

「經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率

或變更原設計之特性及功能」。

2.

「低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改

善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作業之無線電通信。低功率射頻電機須忍

受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾」。

3.

「不致造成違反低功率電波輻射性電機管理辦法之所有控制、調整及開關之使用方法」。

4.

「對任何可能造成違反管理辦法規定之調整予以警告,或建議由具有發射機維修專長之技術人員執行或

由其直接監督及負責」。

5.

「對任何可能造成違反管理辦法之零件

(

晶體、半導體等

)

置換之警告」。

6.

「電磁波曝露量

MPE

標準值

1mW/cm2

,送測產品實測值為:

0.196868 mW/cm2

」。

7.

「本器材須經專業工程人員安裝及設定,始得設置使用,且不得直接販售給一般消 費者」。

8.

「經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率

或變更原設計之特性及功能」。

Safety Guidelines 

Safety Guidelines

The information in this section applies to AP122 devices.

The following safety icons are used in these guidelines to identify the type of precaution:

This icon indicates a general caution. Failure to comply with a caution 
notification can result in damage to equipment.

This icon indicates an electrical caution. Failure to comply with an electrical 

notification can result in serious injury or death, and extensive damage to 

equipment.

This icon indicates a laser caution. Failure to comply with a laser caution can 
result in serious injury.

The following table lists the safety precautions you should follow when installing your AP122 

devices.

Aerohive devices must be installed by a professional installer who is certified to
install these types of devices and to ensure that they are properly grounded 

and meet applicable local and national electrical codes.

Page 7 of 14

AP122 Hardware User Guide

11/14/2016

Содержание AP122

Страница 1: ...n it is important to set the country code to the country in which the AP will be deployed to meet regulatory requirements and for optimal wireless operation To do this follow these steps The country c...

Страница 2: ...nce Statement Europe EU Declaration of Conformity This device complies with the essential requirements of the R TTE Directive 1999 5 EC The following test methods have been applied in order to prove p...

Страница 3: ...99 5 EC Espa ol Spanish Por medio de la presente Aerohive declara que el AP130 cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999 5 CE...

Страница 4: ...er Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes or...

Страница 5: ...operation as appropriate and iv Users should also be advised that high power radars are allocated as primary users i e priority users of the bands 5250 5350 MHz and 5650 5850 MHz and that these radars...

Страница 6: ...equipment complies with ISED RSS 102 radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20 cm 7 8 between the ra...

Страница 7: ...nt This icon indicates an electrical caution Failure to comply with an electrical notification can result in serious injury or death and extensive damage to equipment This icon indicates a laser cauti...

Страница 8: ...e supervised to ensure that they do not play with the devices Electrostatic discharge ESD can damage equipment and impair electrical circuitry ESD damage occurs when electronic components are improper...

Страница 9: ...the AP122 on a wall or other flat surface perform the following steps 1 Make two marks where you want to mount the device on the wall or surface exactly 2 5 64 cm apart 1 Drill two holes that are sli...

Страница 10: ...er and to the network 1 Connect a standard RJ45 Ethernet cable from ETH0 on the AP to a switch 2 If the switch provides PoE power over Ethernet cabling the AP to the switch will power on the AP in a f...

Страница 11: ...ightness bright soft dim off You can adjust the brightness level from bright the default to soft to dim or turn it off completely in HiveManager NG Navigate to Configure Network Policy Additional Sett...

Страница 12: ...NJ 20W EU AH ACC INJ 20W US AH ACC INJ 20W AU AH ACC INJ 20W IL Reset Button Use the Reset button to reset the device or restore the factory default settings Insert a paper clip or similar tool into t...

Страница 13: ...ating frequency Orthogonal Frequency Division Multiplexing OFDM modulation Rates Mbps 54 48 36 24 12 9 6 with auto fallback 802 11n 2 4 2 5 and 5 150 5 850 GHz operating frequency 802 11n modulation R...

Страница 14: ...tions PoE nominal input voltages 48 V Typical PoE power consumption is 11 W RJ45 power input pins Wires 4 5 7 8 or 1 2 3 and 6 Environmental Specifications Operating temperature 32 to 104 F 0 to 40 C...

Отзывы: