background image

Slovensko [Slovenian]

: [Aerohive] izjavlja, da je ta [AP122] v skladu z bistvenimi zahtevami in

ostalimi relevantnimi dolo

č

ili direktive 1999/5/ES.

Slovensky [Slovak]

: [Aerohive] týmto vyhlasuje, že [AP122] sp

ĺň

a základné požiadavky a

všetky príslušné ustanovenia Smernice 1999/5/ES.

Suomi [Finnish]

: [Aerohive] vakuuttaa täten ettät [AP122] tyyppinen laite on direktiivin

1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.

Federal Communication Commission Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection 

against harmful interference in a residential installation. This equipment generates, uses and can 

radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no guarantee that 

interference will not occur in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be determined by turning the equipment 

off and on, the user is encouraged to try to correct the interference by one of the following 
measures:

• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is

connected.

• Consult the dealer or an experienced radio/TV technician for help.

FCC Caution

: Any changes or modifications not expressly approved by the party responsible for 

compliance could void the user's authority to operate this equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 

conditions: (1) This device may not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may cause undesired operation.

This device and its antenna(s) must not be co-located or operating in conjunction with any other 

antenna or transmitter except in accordance with FCC multi-transmitter product procedures. If 

this device operates in the 5.15~5.25 GHz frequency range, it is restricted to indoor use only.

IMPORTANT NOTE:

Radiation Exposure Statement:

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled 

environment. This equipment should be installed and operated with a minimum distance of 

7.8" (20 cm) between the radiator people or animals.

This transmitter must not be co-located or operating in conjunction with any other antenna or 
transmitter.

Canada Regulatory ISED Statements:

This device complies with ISED (Innovation, Science and Economic Development) Canada 

license-exempt RSS standard(s). Operation is subject to the following two conditions:

1. This device may not cause interference, and

Page 4 of 14

AP122 Hardware User Guide

11/14/2016

Содержание AP122

Страница 1: ...n it is important to set the country code to the country in which the AP will be deployed to meet regulatory requirements and for optimal wireless operation To do this follow these steps The country c...

Страница 2: ...nce Statement Europe EU Declaration of Conformity This device complies with the essential requirements of the R TTE Directive 1999 5 EC The following test methods have been applied in order to prove p...

Страница 3: ...99 5 EC Espa ol Spanish Por medio de la presente Aerohive declara que el AP130 cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999 5 CE...

Страница 4: ...er Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes or...

Страница 5: ...operation as appropriate and iv Users should also be advised that high power radars are allocated as primary users i e priority users of the bands 5250 5350 MHz and 5650 5850 MHz and that these radars...

Страница 6: ...equipment complies with ISED RSS 102 radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20 cm 7 8 between the ra...

Страница 7: ...nt This icon indicates an electrical caution Failure to comply with an electrical notification can result in serious injury or death and extensive damage to equipment This icon indicates a laser cauti...

Страница 8: ...e supervised to ensure that they do not play with the devices Electrostatic discharge ESD can damage equipment and impair electrical circuitry ESD damage occurs when electronic components are improper...

Страница 9: ...the AP122 on a wall or other flat surface perform the following steps 1 Make two marks where you want to mount the device on the wall or surface exactly 2 5 64 cm apart 1 Drill two holes that are sli...

Страница 10: ...er and to the network 1 Connect a standard RJ45 Ethernet cable from ETH0 on the AP to a switch 2 If the switch provides PoE power over Ethernet cabling the AP to the switch will power on the AP in a f...

Страница 11: ...ightness bright soft dim off You can adjust the brightness level from bright the default to soft to dim or turn it off completely in HiveManager NG Navigate to Configure Network Policy Additional Sett...

Страница 12: ...NJ 20W EU AH ACC INJ 20W US AH ACC INJ 20W AU AH ACC INJ 20W IL Reset Button Use the Reset button to reset the device or restore the factory default settings Insert a paper clip or similar tool into t...

Страница 13: ...ating frequency Orthogonal Frequency Division Multiplexing OFDM modulation Rates Mbps 54 48 36 24 12 9 6 with auto fallback 802 11n 2 4 2 5 and 5 150 5 850 GHz operating frequency 802 11n modulation R...

Страница 14: ...tions PoE nominal input voltages 48 V Typical PoE power consumption is 11 W RJ45 power input pins Wires 4 5 7 8 or 1 2 3 and 6 Environmental Specifications Operating temperature 32 to 104 F 0 to 40 C...

Отзывы: