5.2.  Repair work 

 
Repair  and  maintenance  work  which  include  the  disassembly  of  the 
turbine must only be performed by professional personnel. 
 
Address your AeroDesignWorks dealer with all service questions. 
 
Returning  of  warranty  cases  can  only  carried  out  by  your  professional 
dealer. Only use original AeroDesignWorks GmbH replacement parts. 
 
When ordering replacement parts, engine type and serial number of the 
turbine must be specified. Maintenance and repair work performed by non 
authorized personnel will lead to expiration of the warranty. 

 
 
6.  Warranty 

 
The  warranty  includes  free  repair  and  replacement  of  parts  with 
manufacturing  or  material  faults  24  months  from  the  date  of  purchase. 
Further liability is excluded. Any costs caused by transport and packaging 
have to be paid by the customer. There is no liability of AeroDesignWorks 
GmbH  concerning  transport  damage.  Before  sending,  please  contact 
AeroDesignWorks GmbH. 
 
An explanation of the error or damage has to be included as well as a valid 
receipt of purchase with the date of purchase. 
 

Any  kind  of  warranty  will  expire  in  case  of  unauthorized  opening, 
disassembly or removal of the housing locking device.

 

 
When returning the turbine to the factory, the ECU must be included so 
we  can  check  the  operation  hours  and  other  operation  parameters.  A 
defective turbine, which does not show any faults in terms of the warranty, 
examination and repair, will be invoiced. Also see terms and conditions of 
AeroDesignWorks 

at 

http://www.aerodesignworks.com/thrust-

turbines/agb/

 on the homepage. 

 

Содержание B100F

Страница 1: ...operating manual B100F B140F...

Страница 2: ...Directions for safe operation 1 1 General safety instructions 1 2 Warning 1 3 Before starting the turbine 1 4 During operation 1 5 After shut off 2 Mounting of the engine 2 1 Mounting options 2 2 Saf...

Страница 3: ...sile loads and temperatures Therefore it cannot be excluded that parts of failing turbine fan wheels and broken fans will strike through the housing which can lead to damage and even injury or death S...

Страница 4: ...is device must read this manual especially the instructions for safe operation Furthermore one has to follow the laws and general rules of the avoiding of accidents technical safety as generally valid...

Страница 5: ...ngine Really make sure to first inform then buy have the fitting size model for your turbine select servos that are powerful enough construct servo wiring and rudder joints very carefully and reinforc...

Страница 6: ...nto the jet exhaust Severe burns can be the result 1 5 After shutting off the engine Place model with the nose facing the wind Wait until the cooling down process is completed Be aware of the cooling...

Страница 7: ...led in a way that the area between ignition plug and cerosin plug is in the 12 o clock position see picture This is absolutely vital for a kerosine start of the B100F B140F engine Else the start i e t...

Страница 8: ...illustration The optimum size of the fuel tank depends on the model but should be at least 1 7 liters The optimum size for the B100F B140F is 2 3 liters which is enough for an average air time of 6 8...

Страница 9: ...perfectly locked in For release push the blue cap in the direction of the metal piece and remove the tube by pulling Now the turbine should be electrically wired to the ECU Connect the turbine via hig...

Страница 10: ...8 activate manual point 2 1 Abgleich adjustment trim and throttle back Enter trim forward Enter Throttle forward Enter Sender is now adjusted Make sure that no sender functions like Dual Rate Expo dis...

Страница 11: ...controlled with the throttle All parameters necessary for operation are now controlled Failure of the turbine or the system are now excluded Conduct a test run of your turbine and also test the range...

Страница 12: ...U features a CODE controlled menu system Every number features an individual menu point From these menu points you have options of changing different pre set parameters This should if at all be done v...

Страница 13: ...mpensation of any kind unless regulated differently by law This includes injury death material damage loss of profit or business interruption of business and other directly or indirectly resulting con...

Страница 14: ...changed after 10 hours of operation The upstream fine filter between pump and turbine should be cleaned every 5 hours of operation Do this very carefully and make sure no particles will enter the fue...

Страница 15: ...faults 24 months from the date of purchase Further liability is excluded Any costs caused by transport and packaging have to be paid by the customer There is no liability of AeroDesignWorks GmbH conce...

Страница 16: ...nds acceleration 50 125 000 rpm 1 0 seconds maintenance interval every 50 hours earlier in case of bearing noise or other reasons B140F diameter 99 0 mm length 296 0 mm weight ca 1240 g max thrust 128...

Страница 17: ...operating manual B100F B140F 2019 06 27 16 8 System installation plan system installation plan for fuel start...

Страница 18: ...ser See technical data fuel consumption Usually 2 3 liter tanks are used with B100F B140F turbines Drill a 6 mm hole in the fuel tank cap of your choice Use the included tank pendulum device and screw...

Страница 19: ...body Then secure the Tygon tube connections with wire Again check for leak tightness Braze the battery cable to your chosen battery Red plus black minus We recommend 3s LiPo batteries with max 12V and...

Страница 20: ...your model the diameter of the extension pipe and the distance from nozzle to nozzle extension must be correct The shorter the nozzle extension the smaller the loss of power The extension pipe must b...

Страница 21: ...B140F 2019 06 27 20 Thank you for your attention Your team of AeroDesignWorks GmbH Wankelstr 57 50996 K ln Tel 49 0 221 984311 50 Fax 49 0 221 984311 02 www aerodesignworks com thrust turbines turbin...

Отзывы:

Похожие инструкции для B100F