operating manual B100F / B140F 2019-06-27
13
5. Maintenance instruction
5.1. Correct maintenance of your turbine
AeroDesignWorks turbines need only little maintenance under normal
operation conditions. However, some points must be considered to
guarantee a faultless function of the engine. This includes regular cleaning
and inspection.
Dirt and grease deposit can cause slippage of the starter unit
clutch. If this happens, clean the tappet rubber und the impeller
nut with a grease-dissolving agent like acetone or liquid gas.
The felt pendulum built into the tank should be cleaned or
changed after 10 hours of operation.
The upstream fine filter between pump and turbine should be
cleaned every 5 hours of operation.
Do this very carefully and make sure no particles will enter
the fuel supply tube. Destruction of the turbine could be
the result!
Make sure the o-ring is in the correct position when screwing
the filter together. Check for leak tightness!
Cover the intake and nozzle areas when the turbine is not in
use.
Keep the turbine in a dry and dust-free place when it is not
used for a longer time. We recommend a dehumidifier to
prevent corrosion.
Check battery condition regularly.
Your turbine’s maintenance interval is at 40 – 50 hours
(about 300 flights). After this time as well as after a special
event (crash, etc.) the turbine should be returned to the
factory.