4.1.3
Determine ventilation approach. Venting to atmosphere is the preferred method.
Alternatively, ventilation may be performed using HVAC, exhaust, etc.
4.1.4
If efficacy testing is being performed, locations and type of biologic indicator should be
noted.
4.1.5
Prior to treatment verify proper time for treatment using the provided treatment injection
time chart.
4.1.6
The RDS 3110 unit uses a computer controller to operate. Use of this controller is
covered in the following section, 4.2 Computer Controller Settings Logic.
4.1.7
Once injection time has been input, collect the required equipment and materials
needed in Section 1.3.
4.1.8
The area is prepared. All drawers, cabinet doors, and bathroom doors will be opened.
4.1.9
The operator puts exposure controls and ventilation approach in place.
4.2
Computer Controller Settings Logic
4.2.1
The RDS 3110 unit settings are prepared using a computer controller interface. The
interface is located on the underside of the lid of the RDS 3110 case.
4.2.2
The computer controller interface will activate when the RDS 3110 is connected to power.
Once the interface has booted up, the main menu screen will appear. (Figure 1, left). Flip
up the red arming switch located to the right of the computer controller to engage the unit.
NOTE:
The error code “PLUG IN PORT CONNECTOR” (Figure 1, right) will appear on the
screen upon engaging the red arming switch. This error code is shown as a reminder to the operator
that an ADP or APA (when in Port Mode, Section 4.3, or a Tripod Mode, Sections 4.6 & 4.7) must
be connected prior to normal operation.