11
1.8 Heat systems
The relevant applicable regulations on the combined use of heat systems, domestic ventilation and extractor hoods (Federal
Association of Chimney Sweeps (ZIV) information) must be observed!
General construction-law requirements
The EVO-R units with heat recovery must only be installed and operated in rooms with heat systems which depend on room air,
if their flue gas venting is monitored by specific (on-site) safety devices, which shut down the EVO-R unit when activated. We
recommend speaking with the competent chimney sweep to take account of possible wishes before procuring a negative
pressure monitoring system for heat systems.
1.9 Performance and technical data
Mechanical connections must be made correctly in order to obtain maximum efficiency from the device. The device's thermal
efficiency, sound level and electrical performance may vary depending on the ambient and operating conditions. These
conditions may affect the measurement result on site and vary from the catalogue data
MODEL
EVO-R
1500
2000
3000
5000
6000
8000
9500
12000
15000
Air flow (m3/h)
1400
2200
2900
4400
5500
8000
9500
12500
15000
Rated current
– ventilation (A)
4,3
6,8
4,6
7,6
7,3
10,9
10,6
15,2
18,2
Rated current
– after-heater (A)
6,1
8,4
13,1
-
-
-
-
-
-
Max. total rated current (A)
2,2
3,4
4,7
7,6
7,3
11
10,7
15,2
18,3
Max. total rated current with electrical
after heater (A)
8,3
11,8
17,7
-
-
-
-
-
-
Power consumption
– ventilation (kW)
1
1,56
3
5
4,8
7,2
7
10
12
Power consumption
– after heater (kW)
4,2
5,8
9,1
-
-
-
-
-
-
Max. power consumption (kW)
1,2
1,8
3,2
5,2
5
7,4
7,4
10,4
12,4
Max. power consumption with electrical
after heater (kW)
5,4
7,6
12,3
-
-
-
-
-
-
Voltage/Frequency
3~400V 50Hz
3~400V 50Hz
3~400V 50Hz
3~400V 50Hz
3~400V 50Hz
3~400V 50Hz
3~400V 50Hz
3~400V 50Hz
3~400V 50Hz
Filter class (extract/ outdoor air)
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
Weight (kg)
230
300
361
629
775
930
1090
1190
1500
IP Class with weather roof
IP54
IP54
IP54
IP54
IP54
IP54
IP54
IP54
IP54
IP Class without weather roof
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
Wiring diagram
Chapter 8.0
Chapter 8.1
Chapter 8.2
Chapter 8.3
Chapter 8.4
Chapter 8.5
Chapter 8.6
Chapter 8.7
Chapter 8.8
MODEL
EVO-R/SO
1500
2000
3000
5000
6000
8000
9500
12000
15000
Air flow (m3/h)
1400
2200
2900
4400
5500
8000
9500
12500
15000
Rated current
– ventilation (A)
4,3
6,8
4,6
7,6
7,3
10,9
10,6
15,2
18,2
Rated current
– after-heater (A)
6,1
8,4
13,1
-
-
-
-
-
-
Max. total rated current (A)
2,2
3,4
4,7
7,6
7,3
11
10,7
15,2
18,3
Max. total rated current with electrical
after heater (A)
8,3
11,8
17,7
-
-
-
-
-
-
Power consumption
– ventilation (kW)
1
1,56
3
5
4,8
7,2
7
10
12
Power consumption
– after heater (kW)
4,2
5,8
9,1
-
-
-
-
-
-
Max. power consumption (kW)
1,2
1,8
3,2
5,4
5,2
7,8
7,6
10,6
12,6
Max. power consumption with electrical
after heater (kW)
5,4
7,6
12,3
-
-
-
-
-
-
Voltage/Frequency
3~400V 50Hz
3~400V 50Hz
3~400V 50Hz
3~400V 50Hz
3~400V 50Hz
3~400V 50Hz
3~400V 50Hz
3~400V 50Hz
3~400V 50Hz
Filter class (extract/ outdoor air)
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
ePM10 50% /
ePM1 55%
Weight (kg)
230
300
361
629
775
930
1090
1190
1500
IP Class with weather roof
IP54
IP54
IP54
IP54
IP54
IP54
IP54
IP54
IP54
IP Class without weather roof
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
Wiring diagram
Chapter 8.0
Chapter 8.1
Chapter 8.2
Chapter 8.3
Chapter 8.4
Chapter 8.5
Chapter 8.6
Chapter 8.7
Chapter 8.8
Содержание EVO-R
Страница 1: ...EVO R COMPACT AIR HANDLING UNIT WITH ROTARY HEAT RECOVERY ...
Страница 129: ...129 Fig 170 Fig 171 ...
Страница 130: ...130 Fig 171 ...
Страница 132: ...132 Fig 173 Fig 174 ...
Страница 133: ...133 Fig 174 ...
Страница 135: ...135 Fig 176 Fig 177 ...
Страница 136: ...136 Fig 177 ...
Страница 138: ...138 Fig 179 Fig 180 ...
Страница 139: ...139 Fig 180 ...
Страница 141: ...141 Fig 182 Fig 183 ...
Страница 142: ...142 Fig 183 ...
Страница 144: ...144 Fig 185 Fig 186 ...
Страница 145: ...145 Fig 186 ...
Страница 147: ...147 Fig 188 Fig 189 ...
Страница 148: ...148 Fig 189 ...
Страница 150: ...150 Fig 191 Fig 192 ...
Страница 151: ...151 Fig 192 ...
Страница 153: ...153 Fig 194 Fig 195 ...
Страница 154: ...154 Fig 195 ...
Страница 155: ...155 ...