16
Aermec 13_01. 5641300_00
NRL 0280-0750 60Hz
EN
Model
0280
0300
0330
0350
0500
0550
0600
0650
0700
0750
Cooling capacity
HA
Alls
Tons
-
-
-
-
24,85
28,95
35,15
40,78
45,13
49,56
HE
Alls
tons
13,05
15,44
17,54
22,15
-
-
-
-
-
-
Total power input
HA
Alls
kW
-
-
-
-
30,10
36,10
42,80
49,40
55,80
60,70
HE
Alls
kW
15,60
18,10
20,80
26,80
-
-
-
-
-
-
Total power input
with LOW PUMP
HA
230V|460V
kW
-
-
-
-
31,94
37,94
45,0
51,6
58,8
63,7
HE
230V|460V
kW
17,01
19,51
22,21
28,21
-
-
-
-
-
-
Total power input
with HIGH PUMP
HA
230V|460V
kW
-
-
-
-
31,95
39,30
45,80
52,40
58,80
64,70
HE
230V|460V
kW
17,95
20,45
23,15
29,15
-
-
-
-
-
-
Total power input
with LOW - PUMP
HA
575V
kW
-
-
-
-
31,20
37,20
45,00
51,60
58,80
63,70
HE
575V
kW
16,70
19,20
21,90
27,90
-
-
-
-
-
-
Total power input
with HIGH - PUMP
HA
575V
kW
-
-
-
-
31,60
38,30
45,80
52,40
58,80
64,70
HE
575V
kW
17,10
19,60
22,30
28,30
-
-
-
-
-
-
Water flow
HA
Alls
gpm
-
-
-
-
60
69
84
98
108
119
HE
Alls
gpm
31
37
42
53
-
-
-
-
-
-
Total pressure drops
HA
Alls
p.s.i.
-
-
-
-
3
4
5
7
8
9
HE
Alls
p.s.i.
2
3
2
3
-
-
-
-
-
-
Useful head
with LOW - PUMP
HA
230V|460V
p.s.i.
-
-
-
-
23
21
22
19
17
16
HE
230V|460V
p.s.i.
22
20
20
19
-
-
-
-
-
-
Useful head
with HIGH - PUMP
HA
230V|460V
p.s.i.
-
-
-
-
37
35
34
31
28
34
HE
230V|460V
p.s.i.
29
29
29
25
-
-
-
-
-
-
Useful head
with LOW - PUMP
HA
575V
p.s.i.
-
-
-
-
18
15
22
19
17
16
HE
575V
p.s.i.
25
24
23
20
-
-
-
-
-
-
Useful head
with HIGH - PUMP
HA
575V
p.s.i.
-
-
-
-
27
25
34
31
28
34
HE
575V
p.s.i.
32
30
30
27
-
-
-
-
-
-
Heating capacity
HA
Alls
BTU/h
-
-
-
-
310778
358582
430885
481999
549901
600571
HE
Alls
BTU/h
165967
196710
220561
267341
-
-
-
-
-
-
Total power input
HA
Alls
kW
-
-
-
-
31,48
37,69
44,70
51,04
58,10
61,35
HE
Alls
kW
16,08
19,08
21,39
28,45
-
-
-
-
-
-
Total power input
with LOW PUMP
HA
230V|460V
kW
-
-
-
-
33,32
39,53
46,90
53,24
61,10
64,35
HE
230V|460V
kW
17,49
20,49
22,80
29,86
-
-
-
-
-
-
Total power input
with HIGH PUMP
HA
230V|460V
kW
-
-
-
-
33,33
40,89
47,70
54,04
61,10
65,35
HE
230V|460V
kW
18,43
21,43
23,74
30,80
-
-
-
-
-
-
Total power input
with LOW PUMP
HA
575V
kW
-
-
-
-
32,58
38,79
46,90
53,24
61,10
64,35
HE
575V
kW
17,18
20,18
22,49
29,55
-
-
-
-
-
-
Total power input
with HIGH PUMP
HA
575V
kW
-
-
-
-
32,98
39,89
47,70
54,04
61,10
65,35
HE
575V
kW
17,58
20,58
22,89
29,95
-
-
-
-
-
-
Water flow
HA
Alls
gpm
-
-
-
-
69
80
96
107
122
133
HE
Alls
gpm
37
44
49
59
-
-
-
-
-
-
Total pressure drops
HA
Alls
p.s.i.
-
-
-
-
4
4
6
7
10
10
HE
Alls
p.s.i.
2
3
3
3
-
-
-
-
-
-
Useful head
with LOW - PUMP
HA
230V|460V
p.s.i.
-
-
-
-
21
19
19
17
14
12
HE
230V|460V
p.s.i.
21
19
19
17
-
-
-
-
-
-
Useful head
with HIGH - PUMP
HA
230V|460V
p.s.i.
-
-
-
-
35
32
33
31
26
28
HE
230V|460V
p.s.i.
30
29
29
27
-
-
-
-
-
-
Useful head
with LOW - PUMP
HA
575V
p.s.i.
-
-
-
-
15
11
19
17
14
12
HE
575V
p.s.i.
24
21
21
18
-
-
-
-
-
-
Useful head
with HIGH - PUMP
HA
575V
p.s.i.
-
-
-
-
25
23
33
31
26
28
HE
575V
p.s.i.
30
28
28
25
-
-
-
-
-
-
ENERGETIC INDEX
EER
HA
Alls
BTU/h/W
-
-
-
-
9,92
9,63
9,86
9,91
9,71
9,81
HE
Alls
BTU/h/W
10,05
10,25
10,13
9,93
-
-
-
-
-
COP
HA
Alls
W/W
-
-
-
-
2,89
2,79
2,83
2,77
2,77
2,87
HE
Alls
W/W
3,03
3,02
3,02
2,75
-
-
-
-
-
-
IPLV
-
Alls
BTU/h/W
13,32
13,42
13,39
13,22
14,75
14,45
15,27
15,16
14,34
14,21
8. TECHNICAL
DATA
"HA - HE" VERSION
HEATING (AHRI CONDITIONS)
Inlet water temperature
40°C / 104 °F
Outlet water temperature
45°C / 113 °F
External air temperature
7°C b.s / 6°C b.u.
COOLING (AHRI CONDITIONS)
Outlet water temperature
6,7°C / 44,06°F
Flow rate
0,043l/s per kW
External temperature
35°C / 95°F
(1)
data refered no pump version
AHRI conditions: leaving water 6,7°C / 44,06°F
flow rate 0,043 l/s per kW (full load)
Load 100% air 35°C / 95°F
Load 75% air 26,7°C / 80°F
Load 50% air 18,3°C / 65°F
Load 25% air 12,8°C / 55°F