Aermec 13_01. 5641300_00
NRL 0280-0750 60Hz
EN
ELECTRONIC REGULATION
GR3
with proportional-integral algorithm: maintains
average output temperature at value set
• Self-adapting differential switch: guarantees
• minimum functioning times of the compressor in
systems with low water content.
• Intelligent defrosting for pressure reduction:
• allows to determine when the coil is effectively defrosted,
avoiding useless defrosting
• Set-point compensation with external temperature
(with external air probe accessory): reduces energy
consumption
• Condensation check based on the pressure rather
than on temperature for absolute stability (with DCPX
revs. adjuster accessory )
• Inverse condensation check for the heat pump functioning
mode also in summer (with DCPX revs. adjuster
accessory)
• Pre-alarms with automatic reset: in the case of alarm,
a certain number of restarts are allowed before the
definitive
• block
• Alarm on the
Δ
T: to identify wiring errors (reverse rotation)
or blocked cycle reversing valve
• Compressor functioning hours count.
• Compressor peak count.
• Historical alarms
• Autostart after voltage drop.
• Local or remote control
Display of the start of the unit:
a.Voltage presence
b. compressor ON/OFF
c. functioning mode (hot/cold)
d. alarm active
Probes, transducers and parameters
display
a. Water outlet
b. water inlet
c. Coil temperature (heat pumps)
d. Pressing gas temperature
e. External air temperature (heat pumps,
cooling only with DCPX and probe)
f. Pressure delivery (heat pumps)
g.Intake pressure (heat pumps)
h. Temperature error (sum of the proportional and integral
error)
i. Stand-by times for start-up/switch-off of the compressor
Alarms management:
a. Low pressure
b. High pressure (primary alarm: switch directly blocks supply
to compressor)
c. High discharge temperature
d. Anti-freeze
e. Water differential flow switch. Alarm on the
Δ
T
−
Alarms with automatic reset with limited number of restarts
before blocking.
−
ON/OFF external contact
−
Change season from external contact
For further information please refer to user manual.
- terminals for REMOTE PANEL,
- spring type control circuit terminal board,
- outdoor electric board with double door and
gaskets,
- electronic controller,
- evaporator pump and recovery pump control
consent relay
- all numbered cables.
DOOR BLOCK DISCONNECTING SWITCH
IT is possible to access the electrical panel by di-
sconnecting the voltage, then using the opening
lever of the panel itself. This lever can be blocked
with one or more padlocks during maintenance,
in order to prevent the machine being powered
up accidentally.
REMOTE CONTROL PANEL PR3
This allows the chiller command operations to
be given from a distance. compressor protection
thermomagnetic switch; fan protection thermo-
magnetic switch; auxiliary protection thermoma-
gnetic switch;
discharge gas temperature control thermostat
CONTROL KEYPAD
Provides full control functions. For a detailed
description refer to the user manual.