TROUBLESHOOTING
Page 23 of 27
Severe icing of cooling
coil (evaporator). An ice
block builds up.
Wrong ambient conditions
or air dehumidifier
defective.
Place the air dehumidifier in a
room with a minimum room
temperature of +10 °C and
wait until the ice has defrosted.
Switch the air dehumidifier on
and let it run for about 3
hours. Should a new ice block
build up, please contact your
specialised dealer. Make sure
to operate the air dehumidifier
in rooms with a minimum
temperature of +3 °C.
Problems may arise of the
dehumidifier is immediately
switched on after storage in
colder environments.
The humidity set on the
hygrostat is not
achieved or the air
dehumidifier does not
automatically switch off.
Hygrostat set to a value <
45% r. h.
Depending on the
environmental conditions, the
air dehumidifier can achieve a
minimum value of 30 percent
relative humidity. Set the
hygrostat to an achievable
value (e. g. to about 50% r. h.)
to ensure that the air
dehumidifier will switch off in
time.
The air dehumidifier is not
sufficiently dimensioned
for the application.
Room temperature, air
exchange rate and open water
surfaces, if any, are decisive for
the humidity load of the room.
Ask your specialized dealer to
calculate the capacity required
for your application.