background image

 

TROUBLESHOOTING 

 

 

 

 

Page 20 of 27 

Spare parts and customer service 

If you have any question concerning the air dehumidifier, or if you need spare 

parts, please contact your authorized dealer or the customer service. 

 

7

 

Troubleshooting 

If problems arise with the dehumidifier please check the following points. Should the 
fault not be located please contact your technical advisor. 

 

WARNING 

Danger of injury by electric shock and risk of material damage 

 

The air dehumidifier may only be repaired by trained 
specialized staff. Within the warranty period, any work on the 
dehumidifier shall only be carried out by the manufacturer or 
persons commissioned by the manufacturer. Any work carried 
out by unauthorized persons shall lead to the forfeiture of all 
warranty claims! 

 

 

 

WARNING 

Danger of injury due to contact with hot components inside the 
air dehumidifier 

 

Work on inside components may only be carried out by the 
manufacturer or personnel authorised by the manufacturer. 

 

 

 

WARNING 

Danger of injury from refrigerants and toxicity 

 

Work on inside components may only be carried out by the 
manufacturer or personnel authorised by the manufacturer. 

 

 

 

WARNING 

Danger of suffocation due to refrigerant leakage in closed rooms 
during maintenance work 

 

Work on inside components may only be carried out by the 
manufacturer or personnel authorised by the manufacturer. 

 

 

 

WARNING 

Danger of injury from rotating fan blade 

 

Repairs or maintenance work may only be carried out by the 
manufacturer or personnel authorised by the manufacturer. 

Содержание BlueDry AD810-P Series

Страница 1: ...MADE IN GERMANY INSTRUCTION MANUAL Air dehumidifier Series AD810 P...

Страница 2: ...hts reserved The instruction manual is based on the technical and product specific parameters The manufacturer reserves the right to add supplementary information to the instruction manual Any use of...

Страница 3: ...11 Electrical connection ______________________________________________________12 Connect condensate drain hose___________________________________________13 Connection of the optional dewpoint kit ___...

Страница 4: ...nts for proper and safety conscious handling of the dehumidifiers must always be met Conventions In this instruction manual you will find notes preceding the operating steps described to warn you of p...

Страница 5: ...ons set out in this manual Hazards from accessories Waste water hoses and air filters must be properly installed and must not disable the protection devices of the condensation dryers The operating el...

Страница 6: ...increased lime deposits in rooms with salt or liquids with a salt content 1 incl brine baths in rooms with ozone treated air in rooms with high solvent concentration in rooms with extreme dust load Pl...

Страница 7: ...ifiers within the limits of designated use also involves observing the specified operating conditions refer to page 11 Any use of the air dehumidifier not in conformity with or going beyond the design...

Страница 8: ...tion The air dehumidifier is equipped with two lateral handles two guide pulleys and two transport rollers Fig 1 AD810 P series air dehumidifier isometric view 1 Front wall air outlet 3 Carrying handl...

Страница 9: ...Page 7 of 27 Fig 2 Series AD810 P air dehumidifier rear view 1 Filter holder 4 Pushbutton for manual draining 2 Air intake area with air filter 5 Amphenol can for dewpoint kit 3 Power cable 6 Condens...

Страница 10: ...Room sensor AD810 P has been fitted with condensate drain pump with which the condensate water is drained The pump has a maximum head of 4 m To close the condensate water hose please use the quick co...

Страница 11: ...into the openings at the front or rear Lift the device with a colleague and use suitable lifting and transport equipment CAUTION Material damage Pulling the power cable may damage the cable Always di...

Страница 12: ...ifting and transport equipment In case of wall mounting use suitable holders and fastening elements according to the weight 1 Report any obvious damage to the carrier parcel service postal service etc...

Страница 13: ...res is inefficient and can result in icing Storage of the air dehumidifier at impermissible temperature conditions can result in damage problems in case of immediate switching on In case of storage be...

Страница 14: ...s must be checked prior to electrical connection of the air dehumidifier The mains voltage must be in conformity with the voltage of the air dehumidifier Socket outlet and supply system must be suffic...

Страница 15: ...the hose Do not place any objects on the hose Check regularly whether condensate is properly discharged 1 Attach the condensate drain hose to the quick coupling Fig 4 page 8 and secure with a hose cl...

Страница 16: ...tute a risk Read the instruction manual before commissioning the air dehumidifier Operating elements AD810 P Fig 5 Operating panel AD810 P 1 Current room humidity 6 Stepwise fan setting 2 Target room...

Страница 17: ...ty is higher than the set humidity value the air dehumidifier will start to work The last values for hygrostat language and fan step are taken over where applicable Operator control Use the arrow keys...

Страница 18: ...fter the room humidity has reached the value set and the sensor measures thawing For living space climate conditions of 20 25 C and 55 65 r h are recommended For quick building drying the hygrostat is...

Страница 19: ...and service WARNING Danger of injury due to contact with hot components inside the air dehumidifier Work on inside components may only be carried out by the manufacturer or personnel authorised by th...

Страница 20: ...t only trained expert staff with inspection and any work inside the air dehumidifier Work on electrical parts of the air dehumidifier may only be carried out by the manufacturer or by authorised quali...

Страница 21: ...er regularly In order to guarantee trouble free functioning of the air dehumidifier also in continuous operation the air dehumidifier in particular the air filter must be checked and cleaned at regula...

Страница 22: ...cturer Any work carried out by unauthorized persons shall lead to the forfeiture of all warranty claims WARNING Danger of injury due to contact with hot components inside the air dehumidifier Work on...

Страница 23: ...C or 35 deg C The unit will start up automatically when the temperature is 5 deg C or 30 deg C again Faults Problem Possible cause Remedy Air dehumidifier shows poor or no humidification performance...

Страница 24: ...t of operation the compressor is working The air dehumidifier is in defrost mode The compressor continues to run not however the fan After a few minutes the fan will automatically start again The air...

Страница 25: ...r is immediately switched on after storage in colder environments The humidity set on the hygrostat is not achieved or the air dehumidifier does not automatically switch off Hygrostat set to a value 4...

Страница 26: ...the on off button to switch the air dehumidifier on 3 Pull the power plug 4 If necessary cover the air dehumidifier with a cloth to protect it from dust Storage To store a single air dehumidifier we...

Страница 27: ...n class IP X4 Protection for indoor swimming pools RCCB to be installed by user Operating conditions 1 C to 34 C 35 r h to 95 r h Type Unit AD810 P Air circulation rate Fan speed I cbm h 1000 Fan spee...

Страница 28: ...ssure in closed indoor rooms The air dehumidifier can prevent the formation of condensation water remove excessive humidity and keep humidity at a defined constant level The air dehumidifier is design...

Страница 29: ...Particular requirements for electrical heat pumps air conditioners and dehumidifiers EN 60204 1 2006 A1 2009 Safety of machinery Electrical equipment of machines Part 1 General requirements EN ISO 13...

Страница 30: ......

Страница 31: ......

Страница 32: ...AERIAL GmbH Systeme zurLuftbehandlung Oststrasse 148 D 22844 Norderstedt Phone 0049 0 40 526879 0 Telefax526 879 20 E Mail info aerial de Internet www aerial de Dealer Stamp...

Отзывы: