Table 3-1: Modulex Data Plate Entries
MODEL NUMBER
MLX-303
MLX-454
MLX-606
MLX-757
MLX-909
MLX-1060
REVISION
A
A
A
A
A
A
TYPE OF GAS
NATURAL GAS
(MLX-303H)
OR PROPANE
(MLX-303HP)
NATURAL GAS
(MLX-454H)
OR PROPANE
(MLX-454HP)
NATURAL GAS
(MLX-606H)
OR PROPANE
(MLX-606HP)
NATURAL GAS
(MLX-757H)
OR PROPANE
(MLX-757HP)
NATURAL GAS
(MLX-909H)
OR PROPANE
(MLX-909HP)
NATURAL GAS
(MLX-1060H
OR PROPANE
(MLX-1060HP)
*SERIAL NO.
303-XX-XXXX
454-XX-XXX
606-XX-XXXX
757-XX-XXXX
909-XX-XXXX
1060-XX-
XXXX
MAX INPUT
303,000
454,000
606,000
757,000
909,000
1,060,000
MIN INPUT
45,000
45,000
45,000
45,000
45,000
45,000
OUTPUT
279,000
418,000
558,000
696,000
835,000
975,000
NET IBR RATING
237,000
355,000
474,000
592,000
710,000
829,000
BOILER CATEGORY
IV
IV
IV
IV
IV
IV
MAX INLET (SUPPLY)
GAS PRESSURE
14” W.C
(34.8 mbar).
14” W.C
(34.8 mbar).
14” W.C
(34.8 mbar).
14” W.C
(34.8 mbar).
14” W.C
(34.8 mbar).
14” W.C
(34.8 mbar).
MIN INLET (SUPPLY)
GAS PRESSURE
4”
(10 mbar)
4”
(10 mbar)
4”
(10 mbar)
4”
(10 mbar)
4”
(10 mbar)
4”
(10 mbar)
*NORMAL MANIFOLD
GAS PRESSURE
3.2” Nat. Gas
(MLX-303H)
2.5” Propane
(MLX-303HP)
3.2” Nat. Gas
(MLX-454H)
2.5” Propane
(MLX-454HP)
3.2” Nat. Gas
(MLX-606H)
2.5” Propane
(MLX-606HP)
3.2” Nat. Gas
(MLX-757H)
2.5” Propane
(MLX-757HP)
3.2” Nat. Gas
(MLX-909H)
2.5” Propane
(MLX-909HP)
3.2” Nat. Gas
(MLX-1060H)
2.5” Propane
(MLX-1060HP)
OPTIMAL INLET
(SUPPLY) GAS
PRESSURE
7.0”
(17.4 mbar)
7.0”
(17.4 mbar)
7.0”
(17.4 mbar)
7.0”
(17.4 mbar)
7.0”
(17.4 mbar)
7.0”
(17.4 mbar)
* NOTE