15
Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up
to standard and in compliance with regulations relating to electrical equipment and must be installed by technically qualified
personnel. The manufacturer assumes no responsibility for damage to persons or property resulting from failure to observe the
regulations contained in this booklet.
1.PRECAUTIONS
• Make sure that the mains supply to the unit is disconnected before performing any installation, service, maintenance or
electrical work!
• The installation and service of the unit and complete ventilation system must be performed by an authorized installer and in
accordance with local rules and regulations.
• If any abnormality in operation is detected, disconnect the device from the mains supply and contact a qualified technician
immediately.
• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
• A wrong electrical wiring can cause damage to the fan and interfere with other electronic devices. In addition to the local safety
requirements, please observe the following actions:
- Separate the power and motor control cables by a minimum of 15cm (6 in);
- Wire each single fan separately;
-
The CTRL-HS can control up to 4 HVLS fans.
• It is recommended that each fan has a dedicated power supply switch since the setting of the Modbus address
to one fan must be carried out when only one fan is connected to the Modbus network.
2.INSTALLATION
Refer to the manual supplied in the control panel packaging or consult the website www.aerauliqa.com
3.WIRING DIAGRAM
Refer to the manual supplied in the control panel packaging or consult the website www.aerauliqa.com
3.1 MODBUS NETWORK INSTALLATION (DAISY CHAIN)
• Use twisted pair cable type
• Minimum 24AWG (0,5mm) cable cross section.
• Run the wires as far away as possible from high voltage AC cables, fluorescent lights, arc welders, and other equipment that
transmits EMI (electromagnetic interference).
• Do not run the twisted-pair cable in conduit with high voltage AC cables.
• Max length of the twisted-pair cable between each fan of the network: 120m (400ft)
CTRL-HS INSTRUCTION
INDEX
1. PRECAUTIONS
15
2. INSTALLATION
15
3. WIRING DIAGRAM
15
3.1 NETWORK INSTALLATION
15
4. OPERATION
16
4.1 HOME PAGE
16
4.2 SETTING OF THE LANGUAGE AND NUMBER OF FANS
17
4.3 SETTING OF THE MODBUS ADDRESSES
18
4.4 ALARM IDENTIFICATION
21
4.5 SETTING
24
4.6 SPEED SETTING
25
4.7 MOTOR INFORMATION
26
4.8 CONTROL SETTING
26
4.9 RUN INPUT SETTING
27
4.10 SYSTEM INFORMATION
27
EN
Содержание CTRL-HS
Страница 28: ...004997 00 1020 ...