Press  and  hold 
20  seconds  and 
released 

Reset Garage Door Controller to Factory Default: 

1.  Make  sure  the  Garage  Door  Controller  is  connected  to  the  power 

supply. 

2.  If  holding  time  more  than  one  second,  the  Network  LED  will  fast 

blink.  If  holding  time  more  than  20seconds,  Network  LED  will  be  on 

for  2  seconds,  which  indicates  the  reset  operation  is  successful, 

otherwise please repeat from step1 to step2. 

 

Note

1.  This  procedure  should  only  be  used  when  the  primary  controller  is 

inoperable.   

2. Reset Garage Door Controller to factory default settings will:   

a), remove Garage Door Controller from Z-Wave network state;   

b), delete the Association setting; 

c), restore the configuration settings to the default. 

Switch 

Button 

Click one time 

Toggle the door to Open/close/stop. 

/- 

Click one time 

Switch the alarm sound to the next sound. 

Press and hold 

Increase or decrease the volume. 

 

 

5. Special Rule of Each Command 
5.1 Z-Wave Plus Info Report Command Class 

Parameter

 

Value

 

Z-Wave Plus Version   

Role Type   

5 (ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SL AVE_ALWAYS_ON) 

Node Type   

0 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE) 

Installer Icon Type   

0x1E00 (ICON_TYPE_GENERIC_BARRIER_OPERATOR) 

User Icon Type   

0x1E00 (ICON_TYPE_GENERIC_BARRIER_OPERATOR) 

 

 

6. Special Rule of Each Command 

6.1 Association CC 

The Garage Door Controller supports 2 association groups and Max 5 nodes for each group..

 

Association 

Group 

Nodes  Send 

Mode 

Send commands 

Group 1 

N/A 

N/A 

Single 

Cast 

When  the  state  of  load(position  status)  is  changed: 

1, Set Configuration parameter 80 to 0

Reserved

Default

2, Set Configuration parameter 80 to 1

Send Hail CC. 

3, Set Configuration parameter 80 to 2: Send the position info. 

[2,5] 

Group 2 

N/A 

N/A 

Содержание ZW062

Страница 1: ...Z Wave Button on the Garage Door Controller 6 If Garage Door Controller has been successfully linked to your Z Wave network its Network LED will no longer blink If the linking was unsuccessful and the Network LED continues to blink repeat the steps above 7 Press the Action Button on the Z Stick to take it out of inclusion mode If you re using a Minimote The Garage Door Controller must be installed...

Страница 2: ...eon Labs will ship the repaired or replacement products to Customer freight prepaid Customer shall indemnify defend and hold Aeon Labs and Aeon Labs affiliates shareholders directors officers employees contractors agents and other representatives harmless from all demands claims actions causes of action proceedings suits assessments losses damages liabilities settlements judgments fines penalties ...

Страница 3: ... Over The Air OTA feature for the product s firmware upgrade 1 Library and Command Classes 1 1 SDK 6 51 06 1 2 Library Basic Device Class BASIC_TYPE_ROUTING_SLAVE Generic Device class GENERIC_TYPE_ENTRY_CONTROL Specific Device Class SPECIFIC_TYPE_SECURE_DOOR 1 3 Commands Class Included Non Secure Network Included Secure Network Node Info Frame COMMAND_CLASS_ZWAVEPLUS_INFO V2 COMMAND_CLASS_SWITCH_B...

Страница 4: ...troller into Z Wave Network 1 Install Garage Door Controller and connect it to the 5V DC Adapter 2 Let the primary controller into inclusion mode If you don t know how to do this please refer to its manual 3 Press the Z Wave Button 4 If the inclusion is failed please repeat the process from step 2 Remove Garage Door Controller from Z Wave Network 1 Install Garage Door Controller and connect it to ...

Страница 5: ... to Open close stop Button Click one time Switch the alarm sound to the next sound Press and hold Increase or decrease the volume 5 Special Rule of Each Command 5 1 Z Wave Plus Info Report Command Class Parameter Value Z Wave Plus Version 1 Role Type 5 ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON Node Type 0 ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE Installer Icon Type 0x1E00 ICON_TYPE_GEN...

Страница 6: ...e 2 Configuration Value n LSB Configuration CC Parameter Number Paramete r Description Default Length 0x20 32 Configure the default startup ringtone Value 0 disable the Startup ringtone Value others Enable and select a startup ringtone for the Garage Door Controller 1 1 0x22 34 Sensor Calibration Calibration Steps 1 Let the garage door move to full close position 2 Send this parameter 0x22 with va...

Страница 7: ... Value4 0 disable the alarm prompt Value4 1 enable the alarm prompt Value1 6 Value2 2 Value3 8 4 0x27 39 Configuration alarm mode when the garage door is in Unknown state 1 Value1 configure the frequency of blinking for the Alarm LED there are 10 levels that 1 to10 level the minimum frequency is level 1 and the max frequency is level 10 2 Value2 configure the alarm sound there are 4 types sound sa...

Страница 8: ...ton will be used to adjust the volume of sound Long pressing the Button will be used to switch the sound to the next Value 1 short pressing the Button will be used to switch the sound to the next Long pressing the Button will be used to adjust the volume of sound 0 1 0x50 80 It will send the Hail CC configuration report CC when the state of garage door is changed 1 Value 0 reserved 2 Value 1 send ...

Страница 9: ...nfiguration locked 1 Value 0 Enable 2 Value 1 Disable 0 1 0xFF 255 1 Value 0x55555555 Default 1 Size 4 Reset to factory default setting and removed from the z wave network 0 4 2 Reset to factory default setting 0 1 Note When you send Configuration get CC to product that will not get the report CC from product if the parameter has no default value ...