![Aeotec ZW062 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/aeotec/zw062/zw062_manual_2861259006.webp)
6
[1,5]
Single
Cast
Forward the Basic Set, Switch Binary Set commands to associated
nodes in Group 2 when the Garage Door Controller receives the
Basic Set, Switch Binary Set commands from main controller.
6.2 Association Group Info Command Class
6.2.1 Association Group Info Report Command Class
Profile: General: NA (Profile MSB=0, Profile LSB=0)
6.2.2 Association Group Name Report Command Class
Group 1
:
Lifeline
Group 2
:
RetransmitSwitchCC
6.3 Configuration Set Command Class
7
6
5
4
3
2
1
0
Command Class = COMMAND_CLASS_CONFIGURATION
Command = CONFIGURATION SET/GET/REPORT
Parameter Number
Default
Reserved
Size
Configuration Value 1(MSB)
Configuration Value 2
………
Configuration Value n(LSB)
Configuration CC(
Parameter Number
)
:
Paramete
r
Description
Default
Length
0x20(32)
Configure the default startup ringtone.
.
Value=0, disable the Startup ringtone.
Value=others, Enable and select a startup ringtone for the
Garage Door Controller.
1
1
0x22 (34)
Sensor Calibration.
Calibration Steps:
1. Let the garage door move to full close position.
2. Send this parameter (0x22) with “value=1” to Garage Door
Controller.
3. Let the garage door move to full open position.
4. Let the garage door move to full close position after the
step 3 is completed.
After the step 4 is complete, all calibration steps are complete.
0
1
0x23 (35)
Set the timeout of all calibration steps for the Sensor.
60
2
0x24 (36)
Get the numbers of alarm music.(not support Set CC)
1
1
0x25 (37)
Configure the alarm mode for when the garage door is
opening.
Value1=10
Value2=1
4