background image

Setting

Description

0

disable

1

enable

Parameter 255: Factory Reset

 
Size: 4 Byte, Default Value: 0

Setting

Description

1

Reset to factory default setting

1431655765

Reset to factory default setting and removed from the zwave network

Technical Data

Dimensions

0.1000000x0.1900000x0.0750000 mm

Weight

510 gr

Hardware Platform

ZM5202

EAN

1220000015548

IP Class

IP 44

Voltage

400V

Load

60A

Device Type

Smart Meter

Firmware Version

01.02

Z-Wave Version

04.22

Certification ID

ZC10-16105288

Z-Wave Product Id

0x0086.0x0002.0x005f

Frequency

Europe - 868,4 Mhz

Maximum transmission power

5 mW

Supported Command Classes

Basic

Meter

Crc 16 Encap

Association Grp Info

Device Reset Locally

Zwaveplus Info

Multi Channel

Configuration

Manufacturer Specific

Powerlevel

Firmware Update Md

Association

Version

Multi Channel Association

Содержание Aeotec

Страница 1: ...es a reliable communication by recon rming every message two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct w...

Страница 2: ...ker should be turned off to perform these installation steps 1 Turn the main breaker off 2 Open the main circuit box panel 3 Clip one clamp of the meter around the incoming electricity cable that conn...

Страница 3: ...es can also be removed from a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller is turned into exclusion respective...

Страница 4: ...uency 3 Remove all dead devices from associations Otherwise you will see severe delays 4 Never use sleeping battery devices without a central controller 5 Dont poll FLIRS devices 6 Make sure to have e...

Страница 5: ...01 power energy detection mode Size 1 Byte Default Value 0 Setting Description 0 report power energy absolute value 1 report positive negative power report the algebraic sum energy 2 report positive n...

Страница 6: ...ort Size 1 Byte Default Value 10 Setting Description 0 100 Valid value Parameter 13 Enable disable reporting Enable disable reporting CRC 16 Encapsulation Command Size 1 Byte Default Value 0 Setting D...

Страница 7: ...Default Value 0 Setting Description 1 reset parameter 111 113 Parameter 111 Setting an automatic report interval Set the report intervall for Group 1 Size 4 Byte Default Value 0 Setting Description 1...

Страница 8: ...dware Platform ZM5202 EAN 1220000015548 IP Class IP 44 Voltage 400V Load 60A Device Type Smart Meter Firmware Version 01 02 Z Wave Version 04 22 Certi cation ID ZC10 16105288 Z Wave Product Id 0x0086...

Страница 9: ...ork Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Noti cation is a special wire...

Отзывы: