always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number

Maximum Nodes

Description

1

5

Send configured Value to devices

2

5

Send configured Value to devices

3

5

Send configured Value to devices

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the
desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the
same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 2: Energy detection mode

For parameters of 101, power, energy detection mode 
Size: 1 Byte, Default Value: 0

Setting

Description

0

report power, energy absolute value

1

report positive/negative power, report the algebraic sum energy

2

report positive/negative power, only report energy positive part (consuming electricity)

3

report positive/negative power, only report energy negative part (generating electricity)

Parameter 3: Selective reporting

Enable selective reporting only when power change reaches a certain threshold or percentage set in 4-11 below. This is used to reduce network traffic. 
Size: 1 Byte, Default Value: 1

Setting

Description

0

disable

1

enable

Parameter 4: Threshold change in wattage

Threshold change in wattage to induce a automatic report (Whole HEM). 
Size: 2 Byte, Default Value: 50

Setting

Description

0 - 60000

Watt

Parameter 5: Threshold change in wattage (Clamp 1)

Threshold change in wattage to induce a automatic report 
Size: 2 Byte, Default Value: 50

Setting

Description

0 - 100

Valid value

Parameter 6: Threshold change in wattage (Clamp 2)

Threshold change in wattage to induce a automatic report 
Size: 2 Byte, Default Value: 50

Setting

Description

0 - 100

Valid value

Parameter 7: Threshold change in wattage (Clamp 3)

Threshold change in wattage to induce a automatic report 
Size: 2 Byte, Default Value: 50

Содержание Aeotec

Страница 1: ...es a reliable communication by recon rming every message two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct w...

Страница 2: ...ker should be turned off to perform these installation steps 1 Turn the main breaker off 2 Open the main circuit box panel 3 Clip one clamp of the meter around the incoming electricity cable that conn...

Страница 3: ...es can also be removed from a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller is turned into exclusion respective...

Страница 4: ...uency 3 Remove all dead devices from associations Otherwise you will see severe delays 4 Never use sleeping battery devices without a central controller 5 Dont poll FLIRS devices 6 Make sure to have e...

Страница 5: ...01 power energy detection mode Size 1 Byte Default Value 0 Setting Description 0 report power energy absolute value 1 report positive negative power report the algebraic sum energy 2 report positive n...

Страница 6: ...ort Size 1 Byte Default Value 10 Setting Description 0 100 Valid value Parameter 13 Enable disable reporting Enable disable reporting CRC 16 Encapsulation Command Size 1 Byte Default Value 0 Setting D...

Страница 7: ...Default Value 0 Setting Description 1 reset parameter 111 113 Parameter 111 Setting an automatic report interval Set the report intervall for Group 1 Size 4 Byte Default Value 0 Setting Description 1...

Страница 8: ...dware Platform ZM5202 EAN 1220000015548 IP Class IP 44 Voltage 400V Load 60A Device Type Smart Meter Firmware Version 01 02 Z Wave Version 04 22 Certi cation ID ZC10 16105288 Z Wave Product Id 0x0086...

Страница 9: ...ork Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Noti cation is a special wire...

Отзывы: