Setting
Description
0
Disable over-load protection
1 - 2415
Threshold power is 1-2145W
Parameter 8: Alarm Response
Enabled by (Alarm Settings), and determines what the switch does in the case an alarm is triggered.When
receives any alarm enabled by Alarm Settings, Indicator Light will keep blinking based on Parameter 0x12 (18).
It will prohibit user from manually or RF control the switch state until the alarm is disable.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Disable, no reaction to alarm settings
1
Switch is ON
2
Switch is OFF
3
Switch will turn ON in 5 seconds, and then turn OFF in 5 seconds in a cycle until user disables
the alarm manually
Parameter 9: Alarm Settings
Determine if alarms are enabled in Switch, and what Switch will react to which alarm. The format of the
parameter is Bit field (Checkboxes). The parameter MUST be treated as a bit field where each individual bit can
be set or reset. A graphical configuration tool SHOULD present this parameter as a series of checkboxes. Please
refer to the manual for more details about supported Notification Type and Notification Event.
Size: 2 Byte, Default Value: 0
Setting
Description
1
Access Control trigger state
256
Smoke Alarm
512
CO Alarm
1024
CO2 Alarm
2048
Heart Alarm
4096
Water Alarm
8192
Access Control
16384
Home Security
Parameter 10: Setting to disable alarm
Determines the method of disabling the alarm of the device.Note:Power off will also disable the alarm response
without any limitation.
Size: 2 Byte, Default Value: 0
Setting
Description
0
Can be disabled by 3x tapping Action Button within 1 second
1
Can be disabled when receives a State Idle corresponding to the alarm. Note: If Access Control is
enable, it also can be disabled when receives the reversal state of window/door.
10 - 255
Sets the duration of the alarm in seconds(i.e. Customer sets this setting to 50, the alarm state of