Setting 

Description 

0 - 2147483647 

Value1=Enable Hour, Value2=Enable Minute, Value3=Disable Hour, Value4=Disabale Minute 

Parameter 91: Threshold Power (W) for inducing automatic report. 

Threshold Power (W) for inducing automatic report.

 

Size: 2 Byte, Default Value: 0 

Setting 

Description 

Disable 

1 - 2300 

1-2300W 

Parameter 92: Threshold Power Consumption (kWh) for inducing automatic report. 

Threshold Power Consumption (kWh) for inducing automatic report.

 

Size: 2 Byte, Default Value: 0 

Setting 

Description 

Disable 

1 - 10000 

1-10000kWh 

Parameter 93: Threshold Current (A) for inducing automatic report. 

Threshold Current (A) for inducing automatic report.

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

Disable 

1 - 100 

0.1-10A. Unit is 0.1A. 

Parameter 101: Configure which meter reading will be periodically report via Lifeline. 

The format of the parameter is Bit field (Checkboxes). The parameter MUST be treated as a bit field where each 
individual bit can be set or reset. A graphical configuration tool SHOULD present this parameter as a series of 
checkboxes.Note:The sending frequency is related to Configuration Parameter 0x6F (111).

 

Size: 4 Byte, Default Value: 15 

Setting 

Description 

Power Consumption 

Power 

Voltage 

Current 

Parameter 111: Configure the sending frequency of Meter Report. 

Configure the sending frequency of Meter Report.

 

Size: 4 Byte, Default Value: 600 

Setting 

Description 

Disable 

600 - 2592000 

600-2592000s. (10minute-30day) 

Parameter 255: Factory Reset or Initialization (Write Only) 

Factory Reset or Initialization (Write Only)

 

Size: 1 Byte, Default Value: 0 

Содержание Aeotec Smart Switch 7

Страница 1: ...SmartStart inclusion No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity 2 Indicator Light will become...

Страница 2: ...r more information about Z Wave technology devices white papers etc please refer to www z wave info Product Description The Aeotec Smart Switch 7 is an elegant appearance small size easy to use Smart...

Страница 3: ...Press Action Button 2 times quickly Product Usage Button Presses and LED reaction Button Press Function when released LED Reaction Power On Unpaired from the network Paired into the network Breathes...

Страница 4: ...ent happens all devices stored in the respective association group will receive the same wireless command wireless command typically a Basic Set Command Association Groups Group Number Maximum Nodes D...

Страница 5: ...bit field where each individual bit can be set or reset A graphical configuration tool SHOULD present this parameter as a series of checkboxes Please refer to the manual for more details about suppor...

Страница 6: ...e of power out Size 1 Byte Default Value 0 Setting Description 0 Last status 1 Switch is on 2 Switch is off Parameter 80 Configure what command will be sent via Lifeline when switch state has changed...

Страница 7: ...ption 0 Disable 1 100 0 1 10A Unit is 0 1A Parameter 101 Configure which meter reading will be periodically report via Lifeline The format of the parameter is Bit field Checkboxes The parameter MUST b...

Страница 8: ...10A Device Type On Off Power Switch Network Operation Always On Slave Z Wave Version 6 81 03 Certification ID ZC10 19066544 Z Wave Product Id 0x0371 0x0003 0x00AF Outdoor Use ok Sensors CurrentPowerV...

Страница 9: ...perated wall controllers Slave is a Z Wave device without capabilities to manage the network Slaves can be sensors actuators and even remote controls Primary Controller is the central organizer of the...

Отзывы: