2
enable, the current PIR sensitivity level = 2.
3
enable, the current PIR sensitivity level=3.
4
enable, the current PIR sensitivity level=4.
5
enable, the current PIR sensitivity level=5. (maximum level)
command sent when the motion sensor triggered. (Parameter Number 5, Parameter Size 1)
Which command would be sent when the
motion sensor triggered.
Value
Description
1
send Basic Set CC.
2
send Sensor Binary Report CC.
low battery value. (Parameter Number 39, Parameter Size 1)
Configure low battery value.
Value
Description
10 — 50
default value = 20 %
selective reporting (Parameter Number 40, Parameter Size 1)
Enable/disable the selective reporting only when measurements reach a
certain threshold or percentage set in 41-44 below. This is used to reduce network traffic.
Value
Description
0
disable (Default)
1
enable
Threshold change in temperature to induce an automatic report. (Parameter Number 41, Parameter Size 2)
1. When the unit is
Celsius, threshold=Value. 2. When the unit is Fahrenheit, threshold=Value*1.8. The accuracy is 0.1. 3. The high byte is the part of integer,
the low byte is the fractional part.
Value
Description
Threshold change in humidity to induce an automatic report. (Parameter Number 42, Parameter Size 2)
The accuracy is 0.1. The
high byte is the part of integer, the low byte is the fractional part.