Press "anion" key to switch it ON; and press it again 

to switch it OFF.

When the anion is open, the anion indicator lamp is 

on; when the anion is closed, the anion indicator 

lamp is off. See fig. 7.6.1.

The atomizing volume of the medical atomizer has two grades, measuring by time and quantity. Press 

"medical atomization" key to start the atomizing function (it is the higher grade with the atomizing volume of 

0.375ml/min and the auto-timing of 10 minutes). Press "atomizing volume regulation" key to switch between 

the higher grade and the lower grade of atomizing volume. The lower grade is 0.5ml/min with the auto-timing 

of 20 minutes. When the medical atomization is started, the atomization indicator lamp is flashing quickly 

(correspondent to the higher grade). Press "regulation" key to adjust it to the lower grade at the time of which 

the indicator lamp is slowly flashing. Press "medical atomization" key again to stop atomization, and the 

atomization indicator lamp is off.

a) Press "atomization" key to start the higher grade; press atomizing volume regulation key "+". To adjust it 

to the lower grade, press atomizing volume regulation key "-". See fig. 7.7.1.

b) Press "atomization" key and get into the medical atomization status (higher grade) during which the 

humidity display and control are shielded. The humidity display shows accumulated atomization time 

counting (in seconds). After atomization and 10 sec delay, it automatically exits the atomization mode and 

reverts to the humidity control mode.

c) During atomization, press "atomization" key to manually stop the atomization mode and revert to the 

humidity control mode.

d) In the atomization mode, the humidity control is not effective. Therefore, when the humidity exceeds the 

maximum set point, there is no alarm. If the humidity still exceeds the maximum set point in three minutes 

after it exits (closes) the medical atomization mode, the alarm is started.

Atomizer water shortage alarm: when the water tank or the medicine cup of the atomizer is short of water, 

stop atomization. The humidity display shows "ELAC" and the atomization lamp is off with water shortage 

alarm. Press "atomization" key again to enter the "atomizer off" status and recover humidity display.

Press illumination adjustment key "+/-" to adjust 

ten grades of illumination intensity. See fig. 7.9.1. 

The highest is grade nine and the lowest is 

closed. Under the Initial start-up status, it is 

closed.

Key control: press "SET" key for five seconds to enter the parameters setting status. The humidity/CO

2

 

display shows flashing digits of CO

2

 concentration set value. When the indicator lamp "P" (CO

2

concentra-

tion) is flashing, it is able to adjust the set value of CO

2

 concentration alarm. Now press humidity "+/-" key 

to adjust CO

2

 set value by±10 stepping. The default factory setting is the alarm set point of 800PPM which 

can be adjusted down to 500PPM and up to 2000PPM. See fig. 7.10.1.

a) On: before starting the sterilization function, make sure that there is no pet in the ICU and the ICU door is 

closed. Meanwhile, press "SET" key plus "sterilization" key to enter the disinfection mode. See fig. 7.8.1.

b) Operation: under this mode, all other function keys are void except "SET" key and "sterilization" key. Both 

temperature display and humidity display show "DISI" (abbreviated disinfection); under the disinfection 

mode, switch on the UV disinfection lamp. There is violet light inside the ICU (with weak acrid scent). 

Meanwhile, start the left fan and the right fan to effect ventilation inside.

c) Off: press "SET" key plus "disinfection" key at the same time again to switch off the UV disinfection lamp, 

the disinfection indication lamp and the left fan to exit the disinfection mode and recover the normal work 

mode. At this time all function keys are valid except the disinfection key.

Note: when the ICU is under the normal work mode, it is invalid to press "disinfection" key individually.

12

13

6. Anion Control Part

8. Disinfection and Sterilization Control Part

9. Illumination Intensity Control

10. CO

2

 Concentration Control

7. Medical Atomization Control

 Figure 7.9.1

 Figure 7.11.1

Press then remove the alarm

Set illumina�on

Press “+”, for brighter

Press “-”, for dimmer ten stage adjustable

 Figure 7.6.1

 Figure 7.7.1

 Figure 7.8.1

Hold press once message come out

Hold and press again for shut down

Press once for start

Press again to shut down

Press “+”, for 10 minutes pa�ern

Press “-”, for 20 minutes pa�ern

Press ones, start to 

nebuilizer, default 

state is for 10 ninute, 

press again for shut down

 Figure 7.10.1

Hold for 5 seconds

Press “+/-” for se�ng the 

valne for co

2

 alarm

Содержание UC-1801

Страница 1: ...Distributor Contacts UC 1803 KO2 10F KO2 2F UC 1801 PETICU INCUBATOR WMS 1501 User Manual Professional Vet Equipments Supplier...

Страница 2: ...the first to introduce computer technology and auxiliary medical devices for pets in the area of ICU control systems This allows for more accurate temperature control of ICU and brings greater conven...

Страница 3: ...d thermostatic incubation cocoon for young pets 2 Allows for body temperature recovery fluid infusion atomization treatment incubation health improving and comfortable stable stay in the hospital for...

Страница 4: ...re 5 1 1 is driven by the circulating air of AEOLUS UC 1801 ICU INCUBATOR Pet ICU Young Pet Incubator After being filtered by the purifier the air from the outside enters into the ICU and dual duct an...

Страница 5: ...the tank and then the scale can be cleaned Silent humidification even humidification and more accurate control Equipped with automatic water cut off protection function When the water supply is cut of...

Страница 6: ...will cause mild nausea poor breathing rapid heartbeat and electrolyte imbalance to pets and seriously affect the health of pets and their postoperative rehabilitation and when the carbon dioxide conce...

Страница 7: ...ature stop cooling step by step and shut down fans after one minute delay c When there is no additionally connected cooler try to place an ice tube inside the atomizing chamber or at the sink as auxil...

Страница 8: ...atus and recover humidity display Press illumination adjustment key to adjust ten grades of illumination intensity See fig 7 9 1 The highest is grade nine and the lowest is closed Under the Initial st...

Страница 9: ...es a Open the cover plate of the right Control Rack b Remove the water tank of the humidifier Remember to disconnect the plug on the water tank beforehand c Brush off the mineral substance such as wat...

Страница 10: ...n of the medical atomizer Atomizing time and volume depend on concentration of atomizing liquid Repeat the atomization operation procedure if not completely atomized once 1 Add water into the water ta...

Страница 11: ...products do not have complete functional performance as required or cannot meet explicitly expressed quality conditions Advance replacement warranty service Your warranty service may involve advance r...

Страница 12: ...vice employees to pick up or you can mail the defective part to the maintenance point We provide our repair or replacement services and parts fees for maintenance after warranty covering shipment cost...

Отзывы: