Product Operation Instructions

A UVC ultraviolet ray is the one that truly has germicidal effect, and C ultraviolet of which is easily absorbed 

by DNA of organisms, especially, ultraviolet ray of 253.7nm is the best. UV sterilizer is a purely physical 

method of disinfection, which is characterized by simple and convenient operation, high efficiency, no 

secondary pollution, easy for management and automation etc.

AEOLUS UC-1801- ICU.INCBATOR uses ultraviolet sterilizer, which is characterized by strong radiation 

intensity, high stability and high transmittance to quartz glass tube. The transmittance is of ≥87% and the 

radiation intensity is at 253.7-254μm and remains stable. Furthermore, high brightness mirror sterilization 

reaction chamber design is adopted. Compared with similar products from abroad, the sterilization strength 

increases by 18%-27%.

---- Generally, the bactericidal action of ultraviolet ray on bacteria and viruses can achieve sterilization rate 

of 99%-99.9% in one to two seconds.

---- The broad-spectrum of ultraviolet sterilization is the highest, and it can efficiently kill almost all bacteria 

and viruses.

---- The ultraviolet sterilizer has no secondary pollution. No chemicals will be added in ultraviolet steriliza-

tion, thus, water and its surrounding environment will not be polluted secondly. Furthermore, it will not 

change any ingredients in the water.

---- The operation of ultraviolet sterilizer is safe and reliable: traditional disinfection technologies such as 

chloride or ozone, the disinfectants themselves are highly toxic and flammable substances, while there is 

no such potential safety hazard in ultraviolet sterilization system.

AEOLUS UC-1801- ICU.INCBATOR is equipped with silent medical atomization function, and biomedical 

engineering research shows: when the atomized particles are about 10 microns, medicines can only 

deposit in the mouth and throat, when the atomized particles are about 3-6 microns, can enter into the 

bronchus, and when the atomized particles are less than 2 microns, medicines can enter into the finest 

bronchus and alveoli. The atomized particles of medicine produced by AEOLUS UC-1801- ICU.INCBATOR 

are 0.5-4 microns. Meanwhile, intelligent control quantity of atomization is provided for your selection, and 

the maximum atomizing volume is up to 0.5ml/min. The atomization in the ICU is even, and the inhalation 

effect of atomized medicines is obvious. The medical built-in atomizer is characterized by low noise, which 

complies with pet ICU noise standard.

AEOLUS UC-1801- ICU.INCBATOR can also provide an external air compressor atomizer you are your 

selection according to users’ preferences and usage, which offers greater choice space.

An increase in carbon dioxide concentration is accompanied by a decrease in oxygen concentration. Being 

anoxic under high concentration of carbon dioxide for a long time will cause pulmonary edema, cerebral 

edema, metabolic acidosis, electrolyte imbalance, shock, hypoxic encephalopathy, etc. When the carbon 

dioxide concentration reaches 1000PPM above, it will cause dizziness, drowsiness and reduced resistance 

to pets; when the carbon dioxide concentration reaches 2000-5000PPM, it will cause mild nausea, poor 

breathing, rapid heartbeat and electrolyte imbalance to pets, and seriously affect the health of pets and their 

postoperative rehabilitation; and when the carbon dioxide concentration is over 5000PPM, it will cause 

severe hypoxia, coma and even death.

set value for three minutes, It will trigger the alarm system and start the intelligent ventilation system at the 

same time, being ventilated with the outside air and thus improve the air quality of ICU, which becomes the 

most important life defense line for pets.

The ICU of AEOLUS UC-1801- ICU.INCBATOR is equipped with a precise carbon dioxide concentration 

monitor, which can monitor changes in carbon dioxide concentration in the ICU. When being hypoxic state 

that concentration exceeds the standard value (exceeds the set value), and cannot be reduced below the 

AEOLUS UC-1801- ICU.INCBATOR uses ten-level LED lights adjustment, which can simulate various 

scenes similar to parent, forest oxygen bar, warm home, forest dawn and dusk twilight, etc., providing a 

cozy and conformable therapeutic environment for pets.

AEOLUS UC-1801- ICU.INCBATOR adopts intelligent alarm system, and is equipped with corresponding 

fault display function, such as extreme temperature and excessive moisture alarm, lack-of-water alarm and 

main components fault warning lights.

AEOLUS UC-1801- ICU.INCBATOR is equipped with intelligent switch power keys, dividing into three 

controls, i.e. power-on, start and power-off. This design is energy saving and safer to use.

All equipment components of AEOLUS UC-1801- ICU.INCBATOR adopt integrated design. All components 

are integrated in a control frame, and completely separated from the control circuit. Only by disassembling 

the control rack, the whole machine can be disassembled to clean various components, including fan, 

medical devices, heat sink and filter etc. The operation is extremely convenient, easy for troubleshooting, 

maintenance and equipment cleaning.

AEOLUS UC-1801- ICU.INCBATOR is equipped with two medical device import Interface channels, thus 

external medical equipment (such as oxygen machine) can be connected into the ICU, meanwhile, the side 

access port adopts medical valve importing design, being convenient for the importing of pets injection and 

infusion needles and relative sealing and fixing.

a) One end of the power cord is plugged into the terminal 

board at the bottom support of the right side of the 

machine, and the other end into the socket of 220V/50Hz 

with reliable grounding. See fig. 7.1.2.

b) The power switch is located at the batter brace of the 

left side of the machine. See fig.7.1.2. It is the on/off 

switch of AEOLUS UC-1801- ICU.INCBATOR. When it is 

locked, all other keys are void; when it is unlocked, all 

other keys are valid.

c) The lock indicator lamp is at the on/off switch. When it 

is on, it means unlocked; when it is off, it means locked. 

08

09

4. Sterilization Function ---- Free from Cross-contamination

7. ICU Illumination Function----Creating Comfortable Therapeutic Environment

8. Setting of Security Mechanism---- No Worries in Use

9. Human Oriented Structural Design ---- Reasonable Operation, Clean and Convenient

1. Start-up and Shutdown

5. Medical Atomization Treatment Function---- Making the Treatment More Convenient

6. Carbon Dioxide Concentration Monitoring Systems----A Defense Line to Guard Life

 Figure 7.1.2

Power ON/OFF

Power Interface

Содержание UC-1801

Страница 1: ...Distributor Contacts UC 1803 KO2 10F KO2 2F UC 1801 PETICU INCUBATOR WMS 1501 User Manual Professional Vet Equipments Supplier...

Страница 2: ...the first to introduce computer technology and auxiliary medical devices for pets in the area of ICU control systems This allows for more accurate temperature control of ICU and brings greater conven...

Страница 3: ...d thermostatic incubation cocoon for young pets 2 Allows for body temperature recovery fluid infusion atomization treatment incubation health improving and comfortable stable stay in the hospital for...

Страница 4: ...re 5 1 1 is driven by the circulating air of AEOLUS UC 1801 ICU INCUBATOR Pet ICU Young Pet Incubator After being filtered by the purifier the air from the outside enters into the ICU and dual duct an...

Страница 5: ...the tank and then the scale can be cleaned Silent humidification even humidification and more accurate control Equipped with automatic water cut off protection function When the water supply is cut of...

Страница 6: ...will cause mild nausea poor breathing rapid heartbeat and electrolyte imbalance to pets and seriously affect the health of pets and their postoperative rehabilitation and when the carbon dioxide conce...

Страница 7: ...ature stop cooling step by step and shut down fans after one minute delay c When there is no additionally connected cooler try to place an ice tube inside the atomizing chamber or at the sink as auxil...

Страница 8: ...atus and recover humidity display Press illumination adjustment key to adjust ten grades of illumination intensity See fig 7 9 1 The highest is grade nine and the lowest is closed Under the Initial st...

Страница 9: ...es a Open the cover plate of the right Control Rack b Remove the water tank of the humidifier Remember to disconnect the plug on the water tank beforehand c Brush off the mineral substance such as wat...

Страница 10: ...n of the medical atomizer Atomizing time and volume depend on concentration of atomizing liquid Repeat the atomization operation procedure if not completely atomized once 1 Add water into the water ta...

Страница 11: ...products do not have complete functional performance as required or cannot meet explicitly expressed quality conditions Advance replacement warranty service Your warranty service may involve advance r...

Страница 12: ...vice employees to pick up or you can mail the defective part to the maintenance point We provide our repair or replacement services and parts fees for maintenance after warranty covering shipment cost...

Отзывы: