Fahrenheit/centigrade can be switched and 

displayed with a toggle key. The default tempera-

ture is shown in centigrade and in two-digit integer 

and one decimal place after which is a letter 

showing special indication at the time of setting the 

temperature parameter. Switch the Fahrenheit/cen-

tigrade indicator lamp. When the indicator lamp 

displays "C", it means centigrade; when it displays 

"F", it means Fahrenheit. See fig. 7.2.1.

Humidity / CO

2

 concentration display can be switched 

with the humidity / CO

concentration key. The default 

is humidity display in two-digit integer and one 

decimal place. CO

2

 concentration is displayed in 

four-digit integer. Switch the humidity / CO

2

 

concentration indicator lamp. When the Indicator 

lamp is "HU", it means humidity; when the indicator 

lamp is "CO

2

", it means CO

concentration. See fig. 

7.3.1.

Key control: press "SET" key plus temperature "+/_" key at the same time to adjust the temperature set 

point, and regulate it by ± 0.1 stepping. See fig. 7.4.1.The factory setting is the set point of 20°C. It can be 

adjusted down to 15°C and up to 38°C;

Smart alarm function:

Alarm for beyond the maximum set point: the temperature and the upper dash are displayed alternately 

every three seconds with alarm and flashing temperature indicator lamp.

Alarm for beyond the minimum set point: the tempera-

ture and the lower dash are displayed alternately every 

three seconds with alarm and flashing temperature 

Indicator lamp.

Damaged temperature sensor: flashing "ERR" display 

and flashing temperature indicator lamp in the 

temperature display.

Control program:

a) When the setting temperature is higher than the measured temperature, start the PID precise heating 

system and left/right fans. When the measured temperature is higher than the setting temperature, stop 

heating step by step.

b) When the measured temperature is higher than the setting temperature, start the PID precise cooling 

system (need additionally purchased cooler) and the left fan to realize ventilation and air exchange inside 

and outside. When the measured temperature is lower than the setting temperature, stop cooling step by 

step and shut down fans after one-minute delay.

c) When there is no additionally connected cooler, try to place an ice tube inside the atomizing chamber or 

at the sink as auxiliary cooling. The system will start the right fan and the left fan to realize ventilation and 

cooling.

    Indicator lamp control:

    Heating---the temperature indicator lamp is red

    Cooling---the temperature indicator lamp is blue

    Delay---the temperature indicator lamp is yellow

Key control: press "SET" key plus humidity "+/-" key 

at the same time to adjust the humidity set point, and 

regulate it by±0.1 stepping. See fig. 7.4.1. The factory 

setting is the humidity set point of 55%. It can be 

adjusted down to 40% and up to 65%.

Alarm function:

a) Alarm for beyond the maximum set point: the 

humidity and the upper dash are displayed alternate-

ly every three seconds with alarm and flashing 

temperature indicator lamp.

b) Alarm for beyond the minimum set point: the 

humidity and the lower dash are displayed alternately every three seconds with alarm and flashing tempera-

ture indicator lamp.

c) Damaged humidity sensor: flashing "ERR" display and flashing humidity indicator lamp in the humidity 

display.

d) Humidifier water shortage alarm (the water level sensor of the humidifier is disconnected): in this case, if 

the humidifier is started, the humidity Indicator lamp is off with water shortage alarm, and the humidity 

display shows "LAC". Meanwhile, it starts the smart water shortage protection system.

Control program:

a) When the setting humidity is higher the measured humidity, start the humidifier and the right fan.

b) When the measured humidity reaches the setting humidity, stop humidifying.

c) When the measured humidity is higher than the setting humidity, start dehumidifying and the left fan; 

reversely start the right fan for air exhaust as auxiliary dehumidifying. If an additionally purchased cooler is 

connected, start the cooling function for dehumidifying.

Indicator lamp control:

The humidity indicator lamp is always on at the time of humidifying.

The humidity indicator lamp is flashing at the time of dehumidifying.

10

11

2. Temperature display

3. Humidity / CO

2

 Concentration Display

5. Humidity Control Part

4. Temperature Control Part

 Figure 7.5.1

Hold

 Figure 7.4.1

Hold

 Figure 7.3.1

 Figure 7.2.1

Содержание UC-1801

Страница 1: ...Distributor Contacts UC 1803 KO2 10F KO2 2F UC 1801 PETICU INCUBATOR WMS 1501 User Manual Professional Vet Equipments Supplier...

Страница 2: ...the first to introduce computer technology and auxiliary medical devices for pets in the area of ICU control systems This allows for more accurate temperature control of ICU and brings greater conven...

Страница 3: ...d thermostatic incubation cocoon for young pets 2 Allows for body temperature recovery fluid infusion atomization treatment incubation health improving and comfortable stable stay in the hospital for...

Страница 4: ...re 5 1 1 is driven by the circulating air of AEOLUS UC 1801 ICU INCUBATOR Pet ICU Young Pet Incubator After being filtered by the purifier the air from the outside enters into the ICU and dual duct an...

Страница 5: ...the tank and then the scale can be cleaned Silent humidification even humidification and more accurate control Equipped with automatic water cut off protection function When the water supply is cut of...

Страница 6: ...will cause mild nausea poor breathing rapid heartbeat and electrolyte imbalance to pets and seriously affect the health of pets and their postoperative rehabilitation and when the carbon dioxide conce...

Страница 7: ...ature stop cooling step by step and shut down fans after one minute delay c When there is no additionally connected cooler try to place an ice tube inside the atomizing chamber or at the sink as auxil...

Страница 8: ...atus and recover humidity display Press illumination adjustment key to adjust ten grades of illumination intensity See fig 7 9 1 The highest is grade nine and the lowest is closed Under the Initial st...

Страница 9: ...es a Open the cover plate of the right Control Rack b Remove the water tank of the humidifier Remember to disconnect the plug on the water tank beforehand c Brush off the mineral substance such as wat...

Страница 10: ...n of the medical atomizer Atomizing time and volume depend on concentration of atomizing liquid Repeat the atomization operation procedure if not completely atomized once 1 Add water into the water ta...

Страница 11: ...products do not have complete functional performance as required or cannot meet explicitly expressed quality conditions Advance replacement warranty service Your warranty service may involve advance r...

Страница 12: ...vice employees to pick up or you can mail the defective part to the maintenance point We provide our repair or replacement services and parts fees for maintenance after warranty covering shipment cost...

Отзывы: