background image

Infrared K-Thermometer Model CA876 

5

 

2.2  Button Functions

2.2.1  Center (Yellow) Button - MEAS

Press this button to turn the thermometer ON and perform a measure-

ment.  When  the  button  is  released,  the  meter  will  automatically  HOLD 

(freeze) the last reading on the display for approximately 15 to 20 seconds 

before automatically shuting OFF.

2.2.2  Mode Button

Pressing this button makes the thermometer enter and advance though 

several  functions  including  some  programmable  functions.  The  MODE 

button is used to select a specific function (e.g. MIN, MAX) or to adjust an 

Alarm or the emissivity.
To enter the mode program, press 

MODE

 once. SET is displayed in lower 

right hand corner.

When pressed consecutively, it will scroll through the following settings:

ε

 

 

ε

 (Set) 

 ALM Hi (Set) 

 ALM Lo (Set) 

 MAX 

 MIN

 K

 

ε

 

SET  is  displayed  in  the  lower  right  hand  corner  of  the  display  when  a 
selected function is programmable (

ε

, ALM Hi, ALM Lo).

ε

Emissivity may be adjusted with the 

 and 

 buttons to match a particu-

lar target. We recommend leaving it at 0.95 for general use.

ALM Hi:

 The Hi alarm set point is adjusted using the 

 and 

 buttons. When 

this set point is reached the beeper will sound and ALM HI will be displayed.

ALM Lo: 

The Lo alarm set point is adjusted using the 

 and 

 buttons. 

When  this  set  point  is  reached  the  beeper  will  sound  and ALM  Lo  will  be 

displayed.

MAX:

 The Max value measured will be displayed during measurement. While 

in the MAX mode and when measuring, the MODE button will toggle the mea-

surement between MAX – MIN – Present reading – MAX.

MIN:

 The Min value measured will be displayed during measurement. While 

in the MIN mode and when measuring, the MODE button will toggle the mea-

surement between MIN – Present reading – MAX – MIN.

K: 

The lower display will indicate the reading from the K-type thermocouple.

NOTE:

 If the thermometer is OFF, pressing the “MEAS” button for more than 

4 seconds will set the thermometer in the MIN/MAX record mode when pow-

ered up.

Содержание CA872

Страница 1: ...INFRARED K THERMOMETER WITH LASER CA876 E N G L I S H User Manual Auto OFF...

Страница 2: ...f the instrument Please record this number and purchase date for your records INFRARED THERMOMETER MODEL CA872 CATALOG 2121 31 SERIAL _ _______________________________________________ PURCHASE DATE __...

Страница 3: ...7 3 1 Environmental Specifications 7 3 1 1 Infrared 7 3 1 2 K Type 8 3 2 General Specifications 9 3 3 Safety Specifications 9 4 OPERATION 10 4 1 Infrared Measurement Considerations 10 4 2 Recommendat...

Страница 4: ...nt errors do not expose the thermom eter to strong electrical or electromagnetic fields To prevent sensor damage and erroneous readings do not put the sensor lens into contact with any body or foreign...

Страница 5: ...the laser beam Laser Output 0 5mW 670nm wavelength 1 2 Receiving Your Shipment Upon receiving your shipment make sure that the contents are consis tent with the packing list Notify your distributor o...

Страница 6: ...ntact when in the IR mode non contact temperature mea surement An aiming laser enables the user to pinpoint the target The K type thermocouple input may also be used The thermometer includes a program...

Страница 7: ...unction is programmable ALM Hi ALM Lo Emissivity may be adjusted with the and buttons to match a particu lar target We recommend leaving it at 0 95 for general use ALM Hi The Hi alarm set point is adj...

Страница 8: ...n turns the laser ON or OFF The symbol is displayed in the upper left hand corner when the laser is ON Remove the laser cover before use The laser is activated when the MEAS button is pressed during a...

Страница 9: ...00 C 2 of Reading or 6 F 3 C whichever is greater 64 4 to 82 4 F 18 to 28 C ambient operating temperature Temperature Coefficient Changes in accuracy operating temperature above 82 4 F 28 C or below 6...

Страница 10: ...C or 1 F C Accuracy 328 F to 1999 F 0 1 of Reading 2 F plus T C 199 C to 1370 C 0 1 of Reading 1 C plus T C Accuracy is specified for operating temperatures over the range of 64 to 82 F 18 to 28 C fo...

Страница 11: ...h battery removed Auto Power Off 15 seconds approx Altitude 2000m max Input Protection 24VDC or 24rms maximum input voltage on any combi nation of inputs Battery Standard 9V battery NEDA 1604 6LR61 or...

Страница 12: ...nd a 5 3 m cut off filter The output signal from the infrared radiation sensor is input to an electronic circuit along with the output signal from a standard temperature sensor to calculate the temper...

Страница 13: ...80 to 0 90 Copper oxide 0 78 Mortar 0 89 to 0 91 Iron oxide 0 78 to 0 82 Brick red 0 93 to 0 96 Textiles 0 90 4 2 Recommendations before Operating If the measured surface target diameter is less than...

Страница 14: ...pressed When the button is released the measurement will be held in the display for 15 20 seconds HOLD is displayed in the lower left hand corner of the display 8 The IR thermometer will shut OFF auto...

Страница 15: ...ermometer is OFF hold down the button then press the MEAS button F will be displayed The selected temperature scale will remain until changed by the user 4 6 Continuous Measurement The user may want t...

Страница 16: ...e LCD display when replacement is needed Replace with a standard 9 volt alkaline battery NEDA 1604 6LR61 To replace the battery Turn the meter OFF Remove the rubber holster Remove the screw from the b...

Страница 17: ...ncludes calibration certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax...

Страница 18: ...ay return the instrument to us for repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty materi...

Страница 19: ...Notes...

Страница 20: ...06 04 99 MAN 100246 v4 Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 Fax 603 742 2346 www aemc com...

Отзывы: