DISARM THE SYSTEM AND CLEAR THE ALARM MEMORY
DISARM THE SYSTEM
In the condition of there is no alarm occurred when you come back from outside.
If the entry beep is enabled, the control console will sound constantly until the ENTRY
DELAY time expires, please put a " " in the box showing your selected option:
OPTION
SELECTED
OPTION
SELECTED
USER CODE
#
The EXIT/ ARMED LED will go OFF and 2 beeps will be heard. The system is disarmed.
If wrong code is entered, 5 beeps will be generated. Enter your user code again after the
5 beeps.
USER CODE
#
This will silence the siren/bell and disarm the system.
The ZONE LEDs on the control console will flash to help you to remember where the
violations occurred.
The alarm memory can be kept as long as you like before you arm the system again.
1) Enter the premises only through a TIME DELAY door.
ENTRY BEEP ENABLED
ENTRY BEEP DISABLED
2) Enter your [USER CODE] and validate by [#] key within the ENTRY DELAY time period.
Enter your [USER CODE] and validate by [#] key.
(DEFAULT: 30 seconds)
(DEFAULT)
!
!
!
!
!
!
DISARM THE SYSTEM AFTER AN ALARM OCCURS
58
HA-266
CONFIGURATION OF THE PROTECTION ZONES
(Location: 21-28)
21
0
0
0
#
The zone can only give alarm once. It
does not accept 2nd triggering to prevent noise pollution. The
zone will be refreshed when the system is reset.
The zone can be re-triggered after alarm was occurred if the
system is still armed.
The zone gives no entry delay and triggers the alarm instantly.
The zone gives entry delay according to the time
setting on the entry delay timer 1.
The zone gives entry delay according to the time
setting on the entry delay timer 2.
The purpose of entry delay 1 and entry delay 2 is to provide
operation convenience for the owner to reach the panel from
different entrances of the house to disarm the system.
entering the house from the garage usually
requires more time than from the main door. With the help of
2 entry delays, the owner can set different entry delay times
for the two entrances.
The zone is always in standby mode, no matter the
system is armed or disarmed. It gives instant alarm whenever it is
triggered.
The zone is always in standby mode, no
matter the system is armed or disarmed. It activates the communicator
and telephone dialer but not the local alarm output
whenever it is triggered. Make sure that either the dialer or the
communicator is enabled for alarm reporting, otherwise, the zone gives
no function and the zone LED will be ON showing that it is a faulty zone.
Loop response time is the time required to trigger a protection Zone.
LOCATIONS
CODE 1 CODE 2 CODE 3
VALIDATION
ZONE LOCATIONS
CODE 1--TRIGGERING MODE
CODE 2--LOOP RESPONSE MODE
CODE 3--LOOP RESPONSE TIME
21=ZONE 1
22=ZONE 2
23=ZONE 3
24=ZONE 4
25=ZONE 5
26=ZONE 6
27=NOT USED 28=ZONE T
0---SINGLE TRIGGER:
1---MULTIPLE TRIGGER:
0---INSTANT:
1---ENTRY DELAY 1:
2---ENTRY DELAY 2:
3---24-HOUR INSTANT:
4---24-HOUR SILENT PANIC:
0 -- 25 mS
2 -- 500 mS
1 -- 250 mS
3 -- 750 mS
(TAMPER SWITCH)
(DEFAULT FOR ALL ZONES)
(no siren and strobe
light)
(DEFAULT FOR ALL ZONES)
REMARK :
For example:
PROGRAMMING THE PANEL
ENTRY OF CODES
RESPONES
ENTRY DELAY 1
ENTRY DELAY 1
INSTANT
INSTANT
24-HR INSTANT
24-HR INSTANT
NOT USE
24-HR INSTANT
ZONE
1
2
3
4
5
6
7
T
CODE
2
1
1
0
0
3
3
-
3
DEFAULT VALUES
FOR CODE 2
19