FACTORY SETTINGS
The system has been programmed with the following default values before exit factory. The
default values can be changed with the programming option values if they are not suitable for
your application.
Please refer to
for details if re-programming is required.
The default programming setup of the alarm system allows the owner to operate the system as
a local alarm panel without programming except the
and the
.
Programming the Panel
Master Code
User Code
LOCATION PARAMETERS
DEFAULT VALUES
PROGRAM DATA
PROGRAMMING
01
10
11-18
Master code
1234 (This is not a default value under the default programming operation. It
is a value that factory put in the system before exit factory) . . . . . .Code=1234
Client code
0000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0000
User code 1-8
Nil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . nil
21
22
23
24
25
26
28
30
31
32
33
34
40
41
50-51
60-63
70
71
72
73
74
76
80
81
82
83
84
HOME
RECORD
85
86
87
Zone 1
Multiple trigger, Entry delay 1, 500mS response. . Code1=1,Code2=1,Code3=2
Zone 2
Multiple trigger, Entry delay 1, 500mS response. . Code1=1,Code2=1,Code3=2
Zone 3
Multiple trigger, Instant, 500mS response . . . . . . . Code1=1,Code2=0,Code3=2
Zone 4
Multiple trigger, Instant, 500mS response . . . . . . . Code1=1,Code2=0,Code3=2
Zone 5
Multiple trigger, 24-Hr Instant, 500mS response . . Code1=1,Code2=3,Code3=2
Zone 6
Multiple trigger, 24-Hr Instant, 500mS response . . Code1=1,Code2=3,Code3=2
Zone T
Multiple trigger, 24-Hr Instant, 500mS response . . Code1=1,Code2=3,Code3=2
Exit delay
Exit beep enabled, 60 seconds . . . . . . . . . . . . . . . . . . . . . . Code=1, duration=60
Entry delay 1
Entry beep enabled, 30 seconds. . . . . . . . . . . . . . . . . . . . . Code=1, duration=30
Entry delay 2
Enter beep enabled, 60 seconds. . . . . . . . . . . . . . . . . . . . . Code=1, duration=60
Siren duration
Arm-disarm ring-back disabled,300 seconds . . . . . . . . . . Code=0, duration=300
Pacifier tones
Enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code=2
Arming type
Forced to arm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code=0
Alarm handover
Disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code=0
Telephone number for communicator
Nil. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . nil
Telephone number for auto-dialer
Nil. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . nil
Dialing attempts for communicator
4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code=4
Dialing attempts for auto-dialer
4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code=4
Recorded message repeats for auto-dialer
4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code=4
Dialing backup/non-backup selection
Non-backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code=0
Listen-in period
60 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . Duration=60
Arm-disarm report
Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code=0
Dialing combination
Communicator OFF, Voice dialer ON . . . . . . . . Code=2
Dialing mode
Tone (DTMF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code=0
Alarm control panel numbering
Disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code=0
Number of rings to pick-up telephone line
16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code=16
Periodic report
Disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code=0
Isolation zones in memory
Nil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . nil
Voice message recorded
Nil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . nil
Power up delay
Disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code=0
Periodic battery test
Disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code=0
Dial-tone and line fault detects
Enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code=1
T
HE PURPOSE OF THE DEFAULT PROGRAMMING SETUP
THE DEFAULT DATA CHART
14
HA-266
TEST THE BACK-UP BATTERY -- MANUAL
TEST THE LOCAL ALARM OUTPUTS
It is highly recommanded to manually test the backup battery from time to time if periodic
battery test is not enabled.
In some cases, manual test of the back-up battery is necessary even periodic test is enabled.
Such as:
To re-test the battery after charging for a period of time. The battery low indicating LED and
the beep sound will be reset after test if the battery that resumes normal was
.
To test a newly replaced battery and to reset the battery low indications - both the beep
sounds and the LED light.
Manual test can be performed at anytime you like.
USER CODE
4
#
Dynamic battery test starts.
Manual test or periodic test takes the same testing routines.
It is highly recommanded to test the alarm outputs of your system from time to time to make
sure that the siren/bell and the strobe light are working properly.
USER CODE
5
#
The alarm output relays connected to the bell/siren, satellite siren and the strobe light will
activate for 3 seconds.
Nothing happen to the communicator and dialer.
!
!
!
!
!
!
!
LOW
Enter your [USER CODE], press the [ ] key, enter number [4] and validate by [#] key.
Enter your [USER CODE], press the [ ] key, enter number [5] and validate by [#] key.
TEST YOUR SYSTEM
63
HA-266