INTRODUCTION
DK-9520 is an universal, self-contained digital access keypad offers field proven reliability and cost effective
solutions for residential and commercial installations. It is designed for stand alone electric lock that operates from
a 12 to 24V AC/DC power supply and virtually compatible with any electric locking device.
DK-9520 consists two application softwares of Single User Mode for the general Users, and Multi-User Mode for
the advanced Users. The system offers a 4 digit length user code with 10,000 combinations in single user mode;
and 100 user codes in length of 4-8 digits with combinations of more than 100 million in multi-user mode.
Independent door lock inhibit authorization code is also available to control the operation of the keypad. Operation
options of Auto Code entry and Manual Code entry are available in both two user modes. Programmed information
that stored in the system are non-volatile in power failure.
Connect to 12-24V AC or DC power supply. The ( ) supply is the common grounding point of the keypad
system. No selection jumper is required for the full input voltage range.
Connect DC power with the (+) and ( ) polarity indicated; and there is no polarity discrimination for AC power
input.
5 Amp relay dry contacts, recommended for door strike controls. Normally Open (N.O.) and Normally Closed
(N.C.) outputs are available. Use N.O. output for Fail-secure locking device and N.C. output for Fail-safe locking
device. The relay can be programmed in Start/Stop (toggle) mode or timer mode from 1 to 999 seconds.
A Normally Open (N.O.) input terminal refers to ( ) ground, with the help of a normally open button to activate
the Output 1 for the same time period as the user code. Egress button is usually put inside the house near the
door. More than one egress buttons can be connected in parallel to the terminal. Leave this terminal open if it is
not used.
12 24V AC/DC
OUTPUT 1
EG IN
-
(POWER INPUT)
(RELAY OUTPUT)
(EGRESS INPUT)
-
-
-
CONNECTION TERMINALS
2
1
2
3
4
5
6
7
8
9
0
#
RED
AMBER
GREEN
DK-9520
R
RELAY
ON OFF
DAP
+
-
12 24V
-
EG
IN
OUTPUT 1
N.C. C. N.O.
DK-9520
11
e)
Operation Voltage:
Operation Modes:
Egress Input:
Relay Output Contacts:
Auto Refreshing Time During Code Entry:
Dimensions:
Try to put some random false codes to the keypad to test its Safety. The keypad generates 5 beeps for
each unsuccessful code entry. The keypad locks itself during 15 minutes after 10 successive false codes
are entered. Normal operation will resume after 15 minutes expired, or, it can be reset with the Master
Code during the locking period.
12V 24V AC/DC, No Jumper is Required for voltage selection
a) Single User Mode, Auto, or Manual Code Entry
b) Multi-User Mode, Auto or Manual Code Entry
b) Multi User Mode ----111,110,000
Output 1 --- 100 user codes for door open (user number 00-99)
Output 2 --- 10 user codes for Inhibit Authorization Control (user number 0-9)
Normally open referring to ( ) ground
Normally Closed and Normally Open Dry Contacts, 5A / 30VDC Max. Rating
a) Each Digit Maximum Entry Time Limit -- 10 seconds
b) Each Code Maximum Entry Time Limit -- 30 seconds
117(H) x 74(W)mm X 48(D)mm
: 160
3289 #
1 03 #
2 1 #
------ Locking is reset and keypad resumes normal operation
If you want to delete User Number 03, press
If you want to delete Authorization code 1, press
D) DELETE USER (MULTI-USER MODE)
If you need to delete a user who has left the company or who no longer has authority to enter the protected area:
Set system in programming mode with the Personal Master Code and the
key
Enter the User Number (00-99 for output relay; 0-9 for authorization code) and the
key to delete a user code
You may delete other user code(s) in this fashion
Exit the programming mode by pressing the
key after the work is done
a) Single User Mode---10,000
g net
1)
2)
3)
4)
User Code Combinations:
Weight
*
3289 *
#
1 05 #
*
------------- The keypad is now in the programming mode
If you want to delete User Number 05, press
Specifications are subject to change for modification without notice
SPECIFICATIONS
-
-