PROGRAMMING AND USE OF THE KEYPAD --
OPERATION EXAMPLES
a)
b)
NOTE:
c)
d)
All programming is accomplished entirely from the front of the keypad. The keypad may be programmed in
your shop or at the installation site. Programmed information is stored in non-volatile memory so it will not
be lost if power is removed.
When programming is required. It is necessary to set the keypad into programming mode first with the
master code and validating it with
key.
If the master code is forgotten, please use DAP jumper to set the keypad into programming mode.
See DAP JUMPER description in previous section for the details.
After the keypad is in programming mode, you may go to any Location for your programming options one by
one, please see Programming Options Summary Chart for the feature details.
You may make continuous programming until all desired options are programmed. Repeated programming at
the same Location is allowed if the previous entry was mistaken.
MASTER CODE
LOCATION 1
OPTION
LOCATION n
OPTION n
I
I
e)
1) Re uirement
Exit programming mode with the
key after all your required options are programmed. The new information
that you have just programmed is saved.
a ) Single User Mode Operation
b) Change the factory-set Master Code 0000 to a Personal Master Code 3289
c ) Set User Code of 8321 for door open
d) Set an Authorization Code of 6854 for inhibit control
e ) Set Output Relay to Momentary Mode, 1 second for door strike
f ) Set Inhibit Authorization Control in Start / Stop Mode
g) Set the keypad to lock itself during 15 minutes after 10 successive false codes
-- 6854 has been stored as Authorization Code for inhibit control
-------------- Inhibit Authorization Control in Start / Stop Mode
data
2) Programming -- Set the above requirement into the keypad:
------- System has been set in programming mode with the factory-set Master Code
------- System has been set for Single User Mode** (please see NOTE (a) below)
-- 3289 has been stored as the new Personal Master Code
Super User Code
-- 8321 has been stored as User Code, for door open
--------- Output Relay has been set to Momentary Mode, 1 second for door strike
----- The keypad has been set to lock during 15 minutes after 10 successive false codes
----------------------- Keypad exits programming mode. All the above
are stored and ready for use
&
A) PROCEDURES OF PROGRAMMING
B) SINGLE USER MODE OPERATION -- An Example
q
8
5
E) Personal Safety
J) Exit Programming Mode
--
Installer Programming
After 10 successive false codes, the keypad locks during 30 seconds
After 10 successive false codes, the Duress output switches to ground
Selectable of after 5 to 10 successive false codes, the keypad locks
00
Disappearance of all the above securities
Keypad exits programming mode and returns to normal operation
5 to 10
during 15 minutes. The keypad can be reset to release locking with
the Master Code at any time during the locking period
1 second notifying beep is given to notify the person outside to open the
door when output relay is activated with an user code or egress button.
Good for the locking device that gives no sound when it activates, such
as a magnetic lock.
Notifying beep disabled and replaced by 2 short successful code entry
beeps for valid user codes
Auto Entry Mode is selected.
key that follows the user code is NOT
required in code entry. The User Codes MUST be set in the same digit
length as the Master Code in Auto Entry Mode and the code length can
be 4-8 digits
Manual Entry Mode is selected.
key that follows the user code is
required in code entry. The user codes can be 4-8 digits and they are
not required to be in the same length as the Master Code
In Single User Mode, no matter the selection is Auto or Manual mode, the Master Code and the User Code
MUST be set in the length of 4 digits.
Pacifier tones available on keypress
All pacifier tones are inhibited. Good for place requires silent environment
F) Output Activation Announcer
G) User Code Entry Mode (Auto or Manual)
H) Pacifier Tones (Keypress Acknowledgement Tones)
--
--
--
Installer Programming
Installer Programming
Installer Programming
NOTE:
Locations
No. of False Entry Validation Comments
Validation
Comments
Locations Code of Functions Validation Comments
Locations Code of Functions Validation Comments
Locations Code of Functions Validation Comments
I) Main LED Flashing ON-OFF -- Installer Programming
Locations
Validation
Code of Functions
Comments
Main LED flashing in normal mode during system standby
Main LED OFF during system standby