background image

EXAMPLES – PROGRAMMING AND OPERATION       

                                                    

1) Example 1 -- EM Card Only :

i) Programming :

     (a)      (b)          (c)              (d)              (e)
(a) The card is programmed for operating Output 1
(b) The operation is medium EM Card only
(c) Take ID number 001 in Group 1 to store the card, which is one of the IDs in 000-999
(d) Put the card close to the reader, one beep confirms the reading
(e) Press # to store the “Card”, two-beep confirms a valid entry

ii) Operation : (while the system is back to operation mode)

 

               (a)

(a) Read the EM card. Two-beep confirms the card is read and Output 1 activates      

2) Example 2 -- Private User Code Only :

i) Programming :

     (a)       (b)         (c)                (d)           (e)
(a) The Private User Code is programmed for operating Output 2
(b) The operation medium is Private User Code only
(c) Take ID number 001 in Group 2 to store the Private User Code, which is one of the IDs in 

001-100 

(d) Put Private User Code “1 2 3 4” into the storage location
(e) Press # to store the “Private User Code”, two-beep confirms a valid entry 

ii) Operation : (while the system is back to operation mode)

 

           (a)              (b)
(a) Key in the Private User Code “1 2 3 4”
(b) Confirm it with the # key. Output 2 activates

Read Card

Read Card



High Traffic Passage:

A short buffer time may be necessary for opening a door outward after pressing the egress button 

for those exits open to a high traffic passage. An egress button with short delay and warning beeps 

helps the user to pay attention to the people passing by to prevent hitting them when the door is 

pushed outward.

Emergency Exit:

Emergency Exit is not open to the public for daily use. It is for emergency case only. It is usually 

closed and watched by guards. The egress button of this keypad can be programmed to offer exit 

delay with warning beeps and even gives alarm output to trigger an alarm system when the door is 

forced to open or the door is open after the exit delay expired. It is an useful tool to get attention of 

the person on duty.

WARNING
Do not enable Egress Delay if instant door open for leaving is the main 
concern in your area.
Make sure the Egress Delay does not affect the safety in your service 
area before enabling the function in Location 90.
The default setting of the system is NO DELAY.



Содержание DK-2852C

Страница 1: ...VANDAL RESISTANT BACK LIT WEATHERPROOF RFID ACCESS CONTROL KEYPAD DK 2852 C D User Manual FOR ELECTRIC LOCK INTER LOCK AND SECURITY SYSTEM INSTALLATIONS AEI PROTECT ON SYSTEMS LIMITED www apo hk com...

Страница 2: ...User Code Common User Codes for Output 1 2 User Codes Card For Output 1 2 Examples Programming And Operation Visitor Codes For Output 1 Only Duress Codes For Outputs 1 2 Operation And Function of The...

Страница 3: ...ct means that no electricity is connected to it It is prepared for free connections The Relay Output contacts provided in this keypad system are dry contacts N C Normally Closed the contact is closed...

Страница 4: ...ation Control Output Relay 2 1A Rating N C N O Contacts for External Door Bell Actuation Control A member of the Tri Tech series keypads compatible with the optional controllers reader keypads for sys...

Страница 5: ...hes to ground when duress code is entered You may use it to turn ON an LED lamp and or a small buzzer to notify a guard or connect it to a 24 hour Normally Open protection zone of an alarm system Only...

Страница 6: ...ILIARY TERMINALS C KEY ACTIVE a b The Key Active Output switches to ground for 10 seconds whenever a key is touched You may use it to turn ON an LED lamp and or a small buzzer to notify a guard or to...

Страница 7: ...the auxiliary readers AR 2802 and the auxiliary reader keypads AR 2806 AR 2807 AR 2809 Total 3 auxiliary readers or reader keypads can be connected in parallel with the Data I O Bus They provide the...

Страница 8: ...ECTION TERMINALS 3 Split decoded Access Control Door Lock Description Apart from stand alone operation the DK 2852 can be up graded to high security Split decoded operation with a decoder unit DA 2800...

Страница 9: ...Warning The keypad generates door forced open warning instantly once the door is forced to open without a valid user Code Card or egress button The warning lasts as long as the time programmed 1 999 s...

Страница 10: ...door position sensing switches for the two doors 16 17 TAMPER N C Tamper Switch Normally Closed Contact A normally closed dry contact while the keypad is secured on its box It is open while keypad is...

Страница 11: ...eep 1 Flash 3 Successful Code Card Entry 2 Beeps 2 Flashes 4 Unsuccessful Code Card Entry 5 Beeps 5 Flashes 5 Power Up Delay Continuous Beeps Continuous Flashes 6 Output Relay Activation 1 Second Long...

Страница 12: ...User Code Operation Media 3 A secondary user code can be repeatedly used for a group of cards in a department Owner can make a proprietary department code for each department in a company Only the sta...

Страница 13: ...with proprietary user code approach is ideal for the area that high security is the main concern This operation mode can also report Duress Alarm by keying in the duress code instead of Secondary user...

Страница 14: ...r power has been applied It is the time frame designed for setting the keypad to programming mode with DAP code See the details of DAP CODE 2 8 2 8 below 1 The keypad gives continuous beeps for 1 minu...

Страница 15: ...ogramming Code The system back to normal opration after programming Pacifier Tone ON OFF 7 1 FUNCTION MODE 0 NO Notification 2 2 Short Beeps 1 1 Second Long Beep FUNCTION MODE 0 OFF 1 ON FUNCTION MODE...

Страница 16: ...ting system program It can not be changed in any ways PROGRAMMING SUMMARY CHART LOCATION FUNCTION ENTRY LIMITS CODE OPTIONS CODE ENTRY FACTORY DEFAULT 0 1 Master Code 4 8 Digits MASTER CODE NIL 0 2 Su...

Страница 17: ...sed with the EM Card It is for example here only f Confirm the Card Code is stored 2 beeps 6 Record an EM Card Commom User Code to Operate The Output 1 for Door Open a b c d e a 10 Programming Locatio...

Страница 18: ...be used to reset an operating output timer instantly Output 1 Activates or Resets Output 2 Activates or Resets Optional Functions Controlled by Super User Code for Output 1 Apart from controlling of t...

Страница 19: ...LIDATION Press key once Two beep confirms the entry or 3 2 1 CLOSE PROGRAMMING MODE Always close programming mode with to set system back to normal Operation after programming The button is equivalent...

Страница 20: ...eps confirms the entry EXAMPLES Example 1 Set Egress Button in Momentary contact of 5 seconds with delay warning beep a b c d a Egress function programming b Momentary contact with warning c Delay tim...

Страница 21: ...card once and confirm It does not require the ID number The Card includes the combinations of 1 Card Only 2 Card Secondary User Code and 3 Card Common User Code 1 2 5 4 3 Location Clearing takes few s...

Страница 22: ...o operation mode a b a Key in the Private User Code 1 2 3 4 b Confirm it with the key Output 2 activates Read Card Read Card High Traffic Passage A short buffer time may be necessary for opening a doo...

Страница 23: ...o prevent unattended leaving shoplifting and unauthorized use of the emergency exits The Intelligent Egress Button can be programmed to do something to get attention from the person on duty before the...

Страница 24: ...e Whole Group of Users Whole group of users including the Codes and Cards can be cleared with the following command a b c a The User Group 1 10 is selected to be cleared 20 for Group 2 b Key in the Gr...

Страница 25: ...on 72 1 LOCATION Key in Location 2 FUNCTION MODES FOR OUTPUT ANNOUNCER Output announcer gives notification beep on the operation status of the outputs There are two notification modes available for th...

Страница 26: ...User Codes must be in 5 digits as well All other User Codes not in 5 digits become invalid When the number of digits reaches the system will check the User Code automatically Good for high traffic acc...

Страница 27: ...e code entry The Duress Codes MUST be in the same digit length with the Master Code for Auto Mode code entry Always set a Duress Code that is easy to remember in Panic Situation Only one number differ...

Страница 28: ...Output 1 b Duress Code ID c The Duress Code e Entry Confirmation iii Pause the real time inhibition manually The real time inhibition can be stopped temporarily if require such as the staff work overt...

Страница 29: ...t in emergency START STOP TIMES FOR DAILY INHIBITION OF OUTPUT 1 Location 56 Setting with start and stop times into the keypad the real time inhibition period for output 1 will recycle daily until the...

Страница 30: ...our real time clock provides the daily time base for starting and stopping the function of inhibition to relay output 1 mainly for electric door lock strike No real time clock setting is required if d...

Страница 31: ...nterference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter...

Отзывы: