Report Duress in EM Card Operation
The Duress Codes are Prime User Codes in the system. In the
“EM Card + Secondary User Code”
or “EM Card + Common User Code”
operation, they can be used to replace the “Secondary User
Code” or the “Common User Code” to operate the specific output and report a duress alarm event.
Programming is not required. The system has the function automatically while Duress Code exists.
Operation : Taking Duress Code 3 3 6 9 in Group 1 for Output 1 As Example
(a) (b) (c)
a) Read the EM card. Two-beeps confirm the reading and 30 seconds waiting time is given for the
entry of Duress Code, the Amber LED keeps flashing
b) Key in the Duress Codes 3 3 6 9 for operating Output 1
c) Confirm it with the key. Output 1 activates in a normal way and the Duress Output also
activates to report Duress Event to an alarm system if connected.
NOTE:
Duress Event can not be reported with EM Card alone. User can only directly use Duress
Read Card
Code to open the door and report duress event in emergency
START & STOP TIMES FOR DAILY INHIBITION OF OUTPUT 1 (Location 56)
Setting with start and stop times into the keypad, the real-time inhibition period for output 1 will
recycle daily until the time settings are cleared.
This function works with the real-time-clock. Set up the real-time at Location 55 is necessary.
For safety reason, the Egress Button is designed always valid. The door lock (controlled by output
1) can be opened with it at anytime during inhibition.
(1) LOCATION
Key in Location
(2) START TIME
– Set the real-time inhibition starting time in Hour and Minute. The allowed time
figure is
00:00 – 23:59
The starting time is based on 24 hours daily with the first two digits for hours and the last two digits
for minutes. The time in second always starts at 0 0.
(3) STOP TIME
– Set the real-time inhibition stopping time in Hour and Minute. The allowed time
figure is
00:00 – 23:59
The stopping time is based on 24 hours daily with the first two digits for hours and the last two digits
for minutes. The time in second always starts at 0 0.
(4) VALIDATION
Press key once.
Two-beep confirms the setting.
STOP TIME
START TIME
VALIDATION
LOCATION
(4)
(3)
HOURS MINUTES
(2)
(1)
HOURS MINUTES