13
16
USB function
As featured with USB output function, the computer board is capable of exporting such test data as
temperature within the recent 10 years via a U disk. After the U disk is plugged in ,the computer
board begins to automatically recognize and import data to the U disk. During data export process,
press “Minus” button, the display panel flashes “USB” , indicating the data export is being in
progress and not completed yet; after 5 seconds of flashing, it exits and shows the actual inside
temperature. If the display panel steadily shows “ALL” , indicating the data export is completed , after
5s, it exits and shows the actual inside temperture. Then, remove the U disk from the USB interface
and plug it into a computer’s USB port to read the data.
USB interface functions:
Control Panel
EL-RG-49H
U disk interface data recording time setting
Press “ Minus ” button for 10s, the inside temperature display area steadily shows “1P” ; press
“ Set ” button, the inside temperature display area flashes Year(factory default : 10), press
“ Minus ” button or “ Plus ” button, select Year from 10-99 (recycling display), e.g., to set 2013,
select 13, press “ Set ” button to save and confirm. Thereafter, the inside temperature display
area steadily shows “2P”, press “ Set ” button, the inside temperature display area flashes Month
(factory default: 01), press “ Minus ” button or “ Plus ” button, select Month from 01-12 (recycling
display) , after selecting the current month, press “ Set ” button to save and confirm. Thereafter,
the inside temperature display area steadily shows “3P”, press “ Set ” button, the inside temperature
display area flashes Date(factory default: 01), press “ Minus ” button or “ Plus ” button, select Date
from 01-31( recycling display), after selecting the current date, press “ Set ” button to save and
confirm. Thereafter, the inside temperature display area steadily shows “4P” ; press “ Set ” button,
the inside temperature display area flashes Hour(factory default: 01), press “ Minus ” button or
“ Plus ” button ,select Hour from 00-23 (recycling display) , after selecting the current hour, press
“ Set ” button to save and confirm. Thereafter, the inside temperature display area steadily shows
“5P”; press “ Minus ” button or “Increase” button, select Minute form 00-99 (recycling display), after
selecting the current minute, press “ Set ” button to save and confirm. Then the inside temperature
display area again shows “1P”, indicating it is possible to reset 1P-5P. After completing settings,
press “ Set ” button for 5s or there is no any operation for 10s to automatically save and exit.
Thereafter, the inside temperature display area normally shows the inside temperature.