Aegis EL-RG-49H Скачать руководство пользователя страница 13

18

11

This product shall be managed by specially-assigned person and checked for operating 
conditions every day with appropriate records. For too high or too low temperature in the 
refrigerator, articles shall be transferred to other storages. No articles shall be stored in the 
refrigerator unless troubles are shot.
This product is pharmaceutical refrigerator with temperature ranging from 2~8

 inside. 

Please make sure articles to be stored conform to environment inside to avoid damages 
of articles and economic loss.
Because of refrigeration inertia, display temperature of the product may differ from actual 
temperature and humidity inside, which is normal.

Pull out the power plug and shut down battery switch if the refrigerator has been 
out of service for long time to prevent electric shock, leakage or fire caused by 
aging power lines.

All refrigerators are refrigerator equipments. Relatively too hot articles must not be put in 
the refrigerator by one time. Otherwise the compressor will not stop for a long time, no 
temperature fall may be apt to burn the compressor. Therefore, articles shall be put in 
batches and cooling shall be conducted in batch until required temperature is reached!
Do not damage refrigerating circuit.
Do not use electrical apparatus without production permit in the refrigerator.

The refrigerator is capable of memorizing set value. When power restores after outage, the 
refrigerator will continue operating according to set parameter before last outage.

The refrigerator shall be reconnected after more than 5 minutes once it is shut 
off, to prevent damage to compressor or system.

If the refrigerator is left unused in areas where supervision is unavailable for a 
long time, make sure children will not get close to the refrigerator and the door 
can not be completely closed.

Operation after Outage

NO. Alarming 

Events

Beeping

Flashing

1

2

3

Over-temp 

rature 

Alarm

(high,low)

Sensor
failure
alarm

Power 

Failure 

Alarm

The refrigerator possesses the alarming, safety and self-diagnosis functions listed in the table below.

Alarming Conditions

When any of upper or lower 

temperature displayed ≥ALH

(Alarm Limit High settable by 
the user),high temperature 
alarming is triggered, while 
when any of upper or lower

temperature shown ≤ALL

(Aalrm LImit Low, settable 
by the user), low temperature 
alarming is triggered.

Display 

Requirements

Remarks

1Hz

Continuous 

beeping

Alarm

light 

flashing

Temperature 

displayed

Remote alarm startup 
when“beeping cancelled” 
is pressed down, both 
remove alarm and 
beeping are cancelled. 
But if it remains alarming 
when after a period of Fd
(settable by the user, the 
default value is 30 mins), 
then beeping and remote 
alarm are restarted 

When power failure or power 
supply (AC220V/110V) switch 
is closed, power failure alarm
is triggered; the power is 
supplied by backup battery
when power failure occurred.

Both 

alarm 

light

and

power

indicator

flashing

The temperature of the 
upper and the lower 
sensors on average 
displayed is 5s(if only 
the upper or the lower 
sensor temperature is 
shown before power 
failure, then the same is 
displayed)

 then the 

screen goes black for 
30s at intervals.

The failure code for short 
circuit or open circuit of the 
upper sensor is E1

It is displayed on the
display board that the 
lower sensor  temp.
alternates with E1, 
which indicates 2s, 
while the temp

.

 shows 

6s.

Alarm

1Hz

Continuous 

beeping

Remote alarm startup 
when“beeping cancelled” 
is pressed down, both 
remove alarm and 
beeping are cancelled. 
But if it remains alarming 
when after a period of Fd
(settable by the user, the 
default value is 30 mins), 
then beeping and remote 
alarm are restarted until 
the power is resupplied. 

Remote alarm startup 
when“beeping cancelled” 
is pressed down, both 
remove alarm and 
beeping are cancelled. 
But if it remains alarming 
when after a period of Fd
(settable by the user, the 
default value is 30 mins), 
then beeping and remote 
alarm are restarted 

The failure code for short 
circuit or open circuit of the 
lower sensor is E2

The failure code for short 
circuit or open circuit of the 
control sensor is E3

1Hz

Continuous 

beeping

Alarm

light 

flashing

It is displayed on the
display board that the 
upper sensor  temp.
alternates with E2, 
which indicates 2s, 
while the temp

.

 shows 

6s.
It is displayed on the
display board that the 
upper and lower sensor  
temp.alternates with E3, 
which indicates 2s, 
while the temp

.

 shows 

6s.

Содержание EL-RG-49H

Страница 1: ...or may vary Translation of the original instruction The scope of the Product Application Pharmaceuticals and other related products which need a storage environment of 2 8 Certi cate of Quality Pharma...

Страница 2: ...harmaceutical Refrigerator Type Designation Trademark EL RG 49H Manufactures Name Aegis Scientific Inc Address Tel 1 Ivybrook Blvd Unit 145R Ivyland PA 18974 USA 1 800 796 2344 Fax 732 879 0248 Refer...

Страница 3: ...essor and main components and better refrigeration performance User friendly design computer control smart and carefree adjust ment not required High performance thermal insulation layer with excellen...

Страница 4: ...the appliance that you have just purchased due to technical improvements 1 Product Feature Content Safety Precautions Precautions for Use Product Installation Component Names Control Panel Applicatio...

Страница 5: ...ug in or pull out the power plug of refrigerator to prevent explosion and fire The refrigerator shall be installed by professional technical staffs or after sale maintenance staffs to prevent electric...

Страница 6: ...ay pose danger to human health or environment Pull out the power plug if the refrigerator has been out of service for long time to prevent electric shock leakage or fire caused by aging power lines If...

Страница 7: ...ust be placed on a solid and flat surface or excessive vibration and noise may be produced when the appliance in operation The appliance can be used by children aged from 8 years and above and persons...

Страница 8: ...hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones the retailer is legally obligated to tak...

Страница 9: ...ion site Do not ground the refrigerator through gas pipes water supply pipes telephone lines or lightning conductors as electric shock may be caused The power plug can be accessed after installation t...

Страница 10: ...ownward upward Clean the back evaporating box Evaporating box is installed on the back of the refrigerator Remove 2 screws on the bottom loosen the upper 2 screws no need to remove them lift the evapo...

Страница 11: ...m is under normal condition When chargeable battery is closed or with too low a power press once the alarm testing key E6 is expected to flash 3 times on the display window at the simultaneously The r...

Страница 12: ...220V 110V failed under any of the above conditions remote alarm shall be started Coupled with 1Hz continuous beeping Take corres ponding measures according to item 1 2 and 3 Remote alarm startup when...

Страница 13: ...upper or lower temperature displayed ALH Alarm Limit High settable by the user high temperature alarming is triggered while when any of upper or lower temperature shown ALL Aalrm LImit Low settable by...

Страница 14: ...inside temperature display area flashes Date press Minus button or Plus button to adjust the current date and the press Set button to save and confirm Thereafter the inside temperature display area sh...

Страница 15: ...e display area steadily shows 2P press Set button the inside temperature display area flashes Month factory default 01 press Minus button or Plus button select Month from 01 12 recycling display after...

Страница 16: ...arameter value After setting press Set to go back and choose other parameters for the same token With all values set press Set button 5s exit and return to the normal display mode Temperature Display...

Отзывы: