Aegis EL-RG-49H Скачать руководство пользователя страница 10

21

8

Forklift or chartered buses are recommended 
for moving the refrigerator before unpacking.
For forklift, the refrigerator shall be accessed 
from the bottom of the wood bracket of the 
refrigerator box side.
For chartered buses, the refrigerator shall be 
accessed from the bottom of the wood bracket, 
and it can be clipped up from both sides of the 
box only.

For safe transportation, equipment of this 
series is fixed on wooden base by metal flat. 
Please unscrew the screws and rotate the 
metal flat to be hidden at the bottom of 
equipment before using

Fig.1

.

Casters are recommended for moving the 
refrigerator after unpacking.

Fig.1

Fig.2

Fig.3

The maximum tilt angle of the refrigerator shall 
be no more than 45° during the course of movement.

Preparation before use

1. Remove the packaging materials and strings

Remove all packaging materials and strings
for transport.

> 300cm from the top

> 10cm from 

the back

> 10cm from

the left

> 10cm

from the

right

2. Count refrigerator accessories accompanied

Check the articles inside the refrigerator against
the packing list; if any difference, contact the
after-sale service.

3. Placing conditions

Leave a gap of 10cm in minimum around the
refrigerator for ventilation and heat dissipation

(

Fig.2

)

.

4. Adjust bracing foot

Rotate the leveling feet with wrench in clockwise
direction to extend them outward and support on
the ground. Make sure the refrigerator will not
move during operation(Fig.3).

Supporting foot

Downward

upward

Clean the back evaporating box

Evaporating box is installed on the back of the refrigerator.
Remove 2 screws on the bottom, loosen the upper 2 screws
(no need to remove them), lift the evaporating box and take 
it out.
Clean the evaporating box.
Reinstall the evaporating box, screw 4 screws firmly.
Clean the box every month. If the refrigerator is used in high 
temperature and high humidity environment, do the cleaning
at least 3 times per month.

The upper screw

Evaporating Box

The bottom screw

Cleaning and Maintenance

Lamp replacement

The refrigerator is equipped with a LED lamp. The lamp has low energy consumption and long 
service life. Any doubt, please contact the after-sales service personnel for changing it.

Component Cleaning

To avoid electric shock or staff injuries, please switch off power of the 
refrigerator before conducting any repairment or maintenance.

Make sure no drug or aerosol around the refrigerator is inhaled during 
maintenance, otherwise your health will be threatened.

Refrigerator cleaning

Clean the refrigerator once a month. Regular cleaning keeps appearance of the refrigerator new.
Wipe off dust in enclosure, inner chamber and all accessories of the refrigerator with dry cloth. If 
the refrigerator is dirty, sweep away dirt with cleaning cloth which has been immersed in neutral 
detergent and wipe off residual detergent with wet cloth, then with dry cloth.
Do not dump water on enclosure or inner chamber of the refrigerator, otherwise electrical 
apparatus insulation may be damaged, causing occurrence of faults.

The compressor and other mechanical parts are completely sealed. No lubrication is required.

Содержание EL-RG-49H

Страница 1: ...or may vary Translation of the original instruction The scope of the Product Application Pharmaceuticals and other related products which need a storage environment of 2 8 Certi cate of Quality Pharma...

Страница 2: ...harmaceutical Refrigerator Type Designation Trademark EL RG 49H Manufactures Name Aegis Scientific Inc Address Tel 1 Ivybrook Blvd Unit 145R Ivyland PA 18974 USA 1 800 796 2344 Fax 732 879 0248 Refer...

Страница 3: ...essor and main components and better refrigeration performance User friendly design computer control smart and carefree adjust ment not required High performance thermal insulation layer with excellen...

Страница 4: ...the appliance that you have just purchased due to technical improvements 1 Product Feature Content Safety Precautions Precautions for Use Product Installation Component Names Control Panel Applicatio...

Страница 5: ...ug in or pull out the power plug of refrigerator to prevent explosion and fire The refrigerator shall be installed by professional technical staffs or after sale maintenance staffs to prevent electric...

Страница 6: ...ay pose danger to human health or environment Pull out the power plug if the refrigerator has been out of service for long time to prevent electric shock leakage or fire caused by aging power lines If...

Страница 7: ...ust be placed on a solid and flat surface or excessive vibration and noise may be produced when the appliance in operation The appliance can be used by children aged from 8 years and above and persons...

Страница 8: ...hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones the retailer is legally obligated to tak...

Страница 9: ...ion site Do not ground the refrigerator through gas pipes water supply pipes telephone lines or lightning conductors as electric shock may be caused The power plug can be accessed after installation t...

Страница 10: ...ownward upward Clean the back evaporating box Evaporating box is installed on the back of the refrigerator Remove 2 screws on the bottom loosen the upper 2 screws no need to remove them lift the evapo...

Страница 11: ...m is under normal condition When chargeable battery is closed or with too low a power press once the alarm testing key E6 is expected to flash 3 times on the display window at the simultaneously The r...

Страница 12: ...220V 110V failed under any of the above conditions remote alarm shall be started Coupled with 1Hz continuous beeping Take corres ponding measures according to item 1 2 and 3 Remote alarm startup when...

Страница 13: ...upper or lower temperature displayed ALH Alarm Limit High settable by the user high temperature alarming is triggered while when any of upper or lower temperature shown ALL Aalrm LImit Low settable by...

Страница 14: ...inside temperature display area flashes Date press Minus button or Plus button to adjust the current date and the press Set button to save and confirm Thereafter the inside temperature display area sh...

Страница 15: ...e display area steadily shows 2P press Set button the inside temperature display area flashes Month factory default 01 press Minus button or Plus button select Month from 01 12 recycling display after...

Страница 16: ...arameter value After setting press Set to go back and choose other parameters for the same token With all values set press Set button 5s exit and return to the normal display mode Temperature Display...

Отзывы: