is full, put the cap back on the hose. Empty the bowl. Repeat the procedure until water
stops flowing out;
5.
clean the pump if necessary as previously described;
6.
replace the emergency emptying hose in its seat after having plugged it;
7.
screw the pump again.
Frost precautions
If the machine is installed in a place where the temperature could drop below 0°C, proceed
as follows:
1.
close the water tap and unscrew the water inlet hose from the tap;
2.
place the end of the emergency emptying hose and that of the inlet hose in a bowl
placed on the floor and let water drain out;
3.
screw the water inlet hose back on and reposition the emergency emptying hose after
having put the cap on again.
By doing this, any water remaining in the machine is removed, avoiding ice forming and
consequently damage to the appliance.
When you use the machine again, make sure that the ambient temperature is above 0°C.
WHAT TO DO IF…
Certain problems are due to lack of simple maintenance or oversights, which can be solved
easily without calling out an engineer. Before contacting your local Service Centre, please
carry out the checks listed below.
During machine operation it is possible that the
yellow
pilot light of button
8
blinks, one of
the following alarm codes appears on the display and at the same time some acoustic sig
-
nals sound every 20 seconds to indicate that the machine is not working:
•
: problem with the water supply
•
: problem with the water draining
•
: door open
Once the problem has been eliminated, press the button
8
to restart the programme. If af
-
ter all checks, the problem persists, contact your local Service Centre.
30
What to do if…
Содержание LAVAMAT 11842 VIT
Страница 85: ...85 ...
Страница 86: ...86 ...
Страница 87: ...87 ...
Страница 88: ...www aeg com shop 132938760 B 092011 ...