AEG AS-M2-G Series Скачать руководство пользователя страница 9

9

AEG GLASS-GLASS MODULE INSTALLATION MANUAL

GD202008 V1-20

EN

self–captivating thread–cutting screw or 8–32 screw 
and hex nut. The grounding clip works with solid 
uninsulated copper wire sizes 10 or 12 AWG.

 Fig.9 SolKip Grounding Clip

3) Additional third-party grounding devices 
AEG solar modules can be grounded using third-party 
grounding devices. It is required that these devices are 
certified for grounding solar modules and are installed 
according to the manufacturer‘s instructions.

4. MAINTENANCE

4.1 General mainteance

If any problem arises, have them investigated by 
a competent specialist; repairing works must be 
performed by specialized and properly trained 
personnel only. Improper maintenance can cause lethal 
electric shock and/or burns.

Use appropriate safety equipment (insulated 
tools, insulating gloves, etc.) when handling 
modules.

For any electrical maintenance, the PV system must be 
shut down first. 
Do not touch live parts or cables and connectors. 
Do not disconnect the grounding when doing system 
maintenance works.

We recommend the following maintenance in 
order to ensure an optimum performance of the 
module:

Check the electrical and mechanical connections every 
six months to verify that they are clean, secure and 
undamaged.
Check that mounting hardware, terminal screws and 
grounding components are tightly secured and are not 
affected by corrosion.
Replacement modules must be of the same type of 
those to be replaced.
Modules generate high voltage when exposed to 
sunlight. Cover the front surface of modules with 
an opaque and not scratching material during 

maintenance.
Follow the maintenance instructions for all components 
used in the system, such as support frames, charge 
regulators, inverters, batteries etc.

4.2 Cleaning

Do not clean modules with broken glass or 
exposed wiring. This can cause a general 
electrical failure of the module or electrical 

shock hazard.

Dirt and dust can accumulate on the glass surface of 
the PV module over time, particularly in installations 
with low inclination. This can cause a general decrease 
of power output and also sedimentation on the 
lower edge of the modules due to dirt accumulation. 
We recommend a periodic cleaning of PV modules 
to ensure maximum power output, especially in 
regions with high quantity of dust in the air or low 
precipitations as follows:

Under most weather conditions, normal rainfall is 
enough to keep the PV module glass surface clean. 
Clean the glass surface of the module as necessary and 
consider that lower inclination requires higher cleaning 
frequency.
  
Always use water and a soft sponge or cloth for 
cleaning. A mild, non-abrasive cleaning agent can be 
used to remove stubborn dirt. High mineral content 
water is not recommended, as it may leave residual 
deposits on the module. 

To avoid a possible thermal shock clean the modules 
during early morning, when the module is still cold. 
This is especially recommended in regions with hotter 
temperatures.

In cold environments with snow do not try to remove 
the frozen snow or ice from the module scratching on 
the front glass. Only soft snow can be removed gently 
with a soft brush.

Do not use abrasive sponges or aggressive tools 
that could scratch the module surface; under no 
circumstance should the dirt be dry removed, as this 
would cause micro-scratches which could have a 
negative impact on the module‘s performances.

Содержание AS-M2-G Series

Страница 1: ...AEG GLASS GLASS MODULE INSTALLATION MANUAL GD202008 V1 20 VERSION AEG SOLAR MODULES INSTALLATION MANUAL GLASS GLASS DOUBLE GLASS MODULE SERIES AS MXXX2 G ...

Страница 2: ...portant information for product care maintenance and disposal CONTENTS 1 1 Icons 2 1 2 Product Identification 2 2 Safety 3 2 1 General safety 3 2 2 Handling safety 3 2 3 Installation safety 3 2 4 Fire safety 4 3 Installation 4 3 1 General remarks 4 3 2 Mechanical installation 5 3 2 1 Bolting 5 3 2 2 Clamping 6 3 2 3 Loading capacity 6 3 3 Electrical Installation and Grounding 7 3 3 1 General remar...

Страница 3: ...ure 2 Example of product technical drawing Please refer to the specific product datasheet on www aeg industrialsolar de for the latest technical data 2 SAFETY 2 1 General safety All AEG PV modules should be installed according to all local and national applicable standards codes and regulations Only qualified personnel should install the solar modules Installers bear the risk of all injury that mi...

Страница 4: ...er metallic devices while installing or troubleshooting photovoltaic systems in order to avoid electric shock Do not disconnect modules under load to avoid electrical arcs Contact with electrically active parts of the modules such as terminals can result in burns sparks and lethal shock whether or not the module is connected Do not insert electrically conductive parts into the plugs and sockets Do...

Страница 5: ...ce of the modules to sea water or lakes should therefore be at least 500 mt unless otherwise specified The module should not be exposed to unusual chemical loads For fire safety indications please see 2 4 Fire safety Protect the solar modules from overvoltage e g voltage peaks of battery charges generators etc If the module has to be connected to a storage battery all precautions as prescribed by ...

Страница 6: ...lting pressure clamps See 3 2 2 Clamping 3 2 1 Bolting Always observe the instructions and safety precautions of the mounting system Modules must be securely fixed to the mounting system support rails using the provided mounting holes There are 4 four mounting holes placed to optimize the load handling capability of the module and to secure it to the supporting structure If increased wind or snow ...

Страница 7: ... Pa Allowed assembly with clamp 0 H 1 4W Allowed assembly with clamp 0 H 1 4W Figure 6 Clamping Loading capacity scheme Mounting by insertion Load positive 1600Pa negative 1600 Pa Load positive 5400 Pa negative 2400 Pa Allowed assembly with clamp 1 2L 50 S 1 2L 50 Figure 7 Insertion Loading capacity scheme 3 3 Electrical Installation and Grounding 3 3 1 General remarks Modules electrically connect...

Страница 8: ...ironmental conditions Always ensure that the modules are assembled with the appropriate string fuse for circuit protection based on the maximum series fuse rating of the module and local electrical installation codes There is no specific limitation on the number of modules that can be connected in parallel the number of modules is determined by system design parameters such as current or power out...

Страница 9: ...ing maintenance Follow the maintenance instructions for all components used in the system such as support frames charge regulators inverters batteries etc 4 2 Cleaning Do not clean modules with broken glass or exposed wiring This can cause a general electrical failure of the module or electrical shock hazard Dirt and dust can accumulate on the glass surface of the PV module over time particularly ...

Страница 10: ...ation use and maintenance of the product are beyond Solar Solutions s control Solar Solutions expressly disclaims liability for loss damage or expense arising out of or in any way connected with such installation operation use or maintenance No responsibility is assumed by Solar Solutions GmbH for any infringement of patents or other rights of third parties which may result from use of the PV prod...

Отзывы: