AEG GLASS-GLASS MODULE INSTALLATION MANUAL

GD202008 V1-20

EN

accordance with the respective National Electrical 
Codes or applicable National Regulations.

3.3.2 Electrical installation

To avoid mismatch, power loss or damage to the PV 
system, do not use different module types within the 
same circuit.

The modules are fitted with two pre-assembled 
sunlight resistant, isolated cable leads, which end with 
PV fast connectors for the electrical connection of 
the system (positive [+] and negative [-] terminals). 
Connectors are Multi-Contact (MC4) or Multi-Contact 
compatible (MC4-compatible). Cables and connectors 
must not be removed or cut off.

Refer to the electrical parameters reported on 
the label of the module when selecting the size 
of the cables connecting the module strings to 

the solar inverter. For electrical design considerations, 
when determining component voltage ratings, 
conductor current ratings, fuse sizes and the rest of 
electrical hardware connected to the module strings, 
the values provided on the module label or on the 
related datasheet should be multiplied by a factor of 
1.25 for Short Circuit Current (Isc) and Open Circuit 
Voltage (Voc). 
Please consult rated local wiring regulations to 
determine system wire size, type, and temperature 
rating of conductors to be connected to module 
connectors. 

The maximum system voltage is 1000 volts or 1500 
volts depending on the product type. Please check the 
product label and datasheet accordingly.

The maximum number of series connected modules 
depends on system design, the type of inverter
used and environmental conditions. Always ensure 
that the modules are assembled with the appropriate 
string fuse for circuit protection based on the maximum 
series fuse rating of the module and local electrical 
installation codes.

There is no specific limitation on the number of 
modules that can be connected in parallel; the number
of modules is determined by system design parameters 
such as current or power output.

To prevent the cables and the connectors from 
overheating, the cross section of the cables and the

capacity of the connectors must be selected to suit the 
maximum system short circuit current. The
recommended PV wire should have a cross section of 
minimum 4mm

2

.

3.3.3 Grounding

Please refer to the respective National Electrical 
Code requirements and standards for safety-related 
grounding of racking system and/or module frames. 
AEG PV Modules use an anodic oxidized aluminum 
frame; modules should hence be connected to the 
equipment grounding conductor to prevent electrical
shock.

The frame rails have pre-drilled holes marked 
with a grounding sign. The grounding holes 
should be used for grounding purposes only and 

not for module mounting.

Grounding methods:
1) Use stainless steel M8 bolt and washer to bond 
the ground wire and aluminum frame through the 
grounding hole (see figure 8) with a tightening torque 
of 3-7N 

• 

m. It is recommended to use a 4-14 mm

2

 

(AWG 6-12) exposed copper wire as ground wire.

 Fig.7 Grounding method with M8 bolt and washer

2) Use of grounding clamps
We recommend the use of SolKlip Grounding 
Clip Assemblies 1954381 for safety purposes. The 
grounding clip assembly consists of a slider, base, and 

Laminate

Nut

Spring washer
Star washer
Grounding hole

Ground wire

Flat washer

Flat washer

Screw

Grounding clip

Earth wire

Frame

Содержание AS-M2-G Series

Страница 1: ...AEG GLASS GLASS MODULE INSTALLATION MANUAL GD202008 V1 20 VERSION AEG SOLAR MODULES INSTALLATION MANUAL GLASS GLASS DOUBLE GLASS MODULE SERIES AS MXXX2 G ...

Страница 2: ...portant information for product care maintenance and disposal CONTENTS 1 1 Icons 2 1 2 Product Identification 2 2 Safety 3 2 1 General safety 3 2 2 Handling safety 3 2 3 Installation safety 3 2 4 Fire safety 4 3 Installation 4 3 1 General remarks 4 3 2 Mechanical installation 5 3 2 1 Bolting 5 3 2 2 Clamping 6 3 2 3 Loading capacity 6 3 3 Electrical Installation and Grounding 7 3 3 1 General remar...

Страница 3: ...ure 2 Example of product technical drawing Please refer to the specific product datasheet on www aeg industrialsolar de for the latest technical data 2 SAFETY 2 1 General safety All AEG PV modules should be installed according to all local and national applicable standards codes and regulations Only qualified personnel should install the solar modules Installers bear the risk of all injury that mi...

Страница 4: ...er metallic devices while installing or troubleshooting photovoltaic systems in order to avoid electric shock Do not disconnect modules under load to avoid electrical arcs Contact with electrically active parts of the modules such as terminals can result in burns sparks and lethal shock whether or not the module is connected Do not insert electrically conductive parts into the plugs and sockets Do...

Страница 5: ...ce of the modules to sea water or lakes should therefore be at least 500 mt unless otherwise specified The module should not be exposed to unusual chemical loads For fire safety indications please see 2 4 Fire safety Protect the solar modules from overvoltage e g voltage peaks of battery charges generators etc If the module has to be connected to a storage battery all precautions as prescribed by ...

Страница 6: ...lting pressure clamps See 3 2 2 Clamping 3 2 1 Bolting Always observe the instructions and safety precautions of the mounting system Modules must be securely fixed to the mounting system support rails using the provided mounting holes There are 4 four mounting holes placed to optimize the load handling capability of the module and to secure it to the supporting structure If increased wind or snow ...

Страница 7: ... Pa Allowed assembly with clamp 0 H 1 4W Allowed assembly with clamp 0 H 1 4W Figure 6 Clamping Loading capacity scheme Mounting by insertion Load positive 1600Pa negative 1600 Pa Load positive 5400 Pa negative 2400 Pa Allowed assembly with clamp 1 2L 50 S 1 2L 50 Figure 7 Insertion Loading capacity scheme 3 3 Electrical Installation and Grounding 3 3 1 General remarks Modules electrically connect...

Страница 8: ...ironmental conditions Always ensure that the modules are assembled with the appropriate string fuse for circuit protection based on the maximum series fuse rating of the module and local electrical installation codes There is no specific limitation on the number of modules that can be connected in parallel the number of modules is determined by system design parameters such as current or power out...

Страница 9: ...ing maintenance Follow the maintenance instructions for all components used in the system such as support frames charge regulators inverters batteries etc 4 2 Cleaning Do not clean modules with broken glass or exposed wiring This can cause a general electrical failure of the module or electrical shock hazard Dirt and dust can accumulate on the glass surface of the PV module over time particularly ...

Страница 10: ...ation use and maintenance of the product are beyond Solar Solutions s control Solar Solutions expressly disclaims liability for loss damage or expense arising out of or in any way connected with such installation operation use or maintenance No responsibility is assumed by Solar Solutions GmbH for any infringement of patents or other rights of third parties which may result from use of the PV prod...

Отзывы: