Do not remove any attached nameplates or 
components
Do not exceed the maximum stapling limitation of 2 
pallets (standard packaging for shipment).
After unpacking, the modules should be laid 
horizontally. Do not incline or stack the modules.
Do not pile up modules without protections to prevent 
scratches to the glass and frame. Should the modules 
need to be piled, they need to be separated by special 
paper or plastic angles.
Do not scratch or damage the module surface.
Do not drill holes in the frame as it may compromise its 
strength, cause corrosion and void the warranty.
Do not use the junction box and cables as a grip.
Do not drop the module or allow objects to fall on the 
module.
Do not place any heavy objects on the module to avoid 
glass breakage.
Do not stand or step on the module. 
Do not set the module down hard on a surface.

Do not attempt to repair a module with broken 
glass or torn backsheet and do not use it as 
contact with any module surface or the frame 

could cause an electric shock.

2.3 Installation safety 

Installing solar photovoltaic systems requires 
specialized skills and knowledge. Photovoltaic solar 
modules are designed for outdoor use, and may be 
ground mounted as well as mounted on rooftops, 
vehicles or boats. The proper design of support 
structures is a responsibility of the system designer 
and installer. When installing the system, abide with 
all local, regional and national statutory regulations.  
Keep children away from the installation site and 
during transportation and installation of the electrical 
equipment.

Cover the module completely with a dark opaque 
material during installation to prevent electricity 
generation. 
When working with modules without any cover, the 
safety regulations for live electrical equipment need to 
be followed. Use only equipment, connectors, wiring 
and support frames suitable for use in a solar electric 
installation. 

Do not wear metallic rings, watchbands, ear, 
nose or lip rings or other metallic devices while 
installing or troubleshooting photovoltaic 

systems in order to avoid electric shock.

Do not disconnect modules under load to avoid 
electrical arcs.
Contact with electrically active parts of the modules, 
such as terminals, can result in burns, sparks and
lethal shock whether or not the module is connected.
Do not insert electrically conductive parts into the 
plugs and sockets.
Do not install solar modules and wiring with wet plugs 
and sockets.
Exert extreme caution when carrying out any work on 
the wiring. High contact voltages can generate in the 
inverter when it is isolated.
Abide with the safety regulations for all the other 
components used in the PV system, including wiring 
and cables, connectors, charging regulators, inverters, 
storage batteries and rechargeable batteries, etc 
 

One individual module may generate DC 
voltages greater than 30 V when exposed to 
light of any intensity. Contact with a DC voltage 

of 30 V or more is potentially hazardous. The series or 
parallel connection of the modules increases the 
voltage or electric current respectively. The electrical 
characteristics are within ±3 % of the indicated values 
of Isc, Voc and Pmax under standard test conditions 
(irradiance of 1000 W/m², AM 1.5 spectrum, and a cell 
temperature of 25 °C/77 °F ). Under normal conditions, 
a photovoltaic module is likely to experience conditions 
that produce more current and/or voltage than 
reported at standard test conditions. Accordingly, the 
values of Isc and Voc marked on the module should be 
multiplied by a factor of 1.25 when determining 
component voltage ratings, conductor current ratings, 
minimum factor of fuse sizes, and size of controls 
connected to the PV output.

2.4 Fire safety 

AEG PV modules are tested according to the provisions 
of IEC EN 61730 Directive with Application Class A. Fire 
safety has been rated as Class C. 

!

Please be aware that rooftop installations can 
affect the fire safety of a building. Rooftop 
installations should be placed over fire resistant 

roofs only; fire class A is recommended. Only fire-
resistant components should be used for rooftop 
installations.

Do not install the solar panels in the proximity of 
sources of flammable gases and vapors or open flames.

Содержание AS-M2-G Series

Страница 1: ...AEG GLASS GLASS MODULE INSTALLATION MANUAL GD202008 V1 20 VERSION AEG SOLAR MODULES INSTALLATION MANUAL GLASS GLASS DOUBLE GLASS MODULE SERIES AS MXXX2 G ...

Страница 2: ...portant information for product care maintenance and disposal CONTENTS 1 1 Icons 2 1 2 Product Identification 2 2 Safety 3 2 1 General safety 3 2 2 Handling safety 3 2 3 Installation safety 3 2 4 Fire safety 4 3 Installation 4 3 1 General remarks 4 3 2 Mechanical installation 5 3 2 1 Bolting 5 3 2 2 Clamping 6 3 2 3 Loading capacity 6 3 3 Electrical Installation and Grounding 7 3 3 1 General remar...

Страница 3: ...ure 2 Example of product technical drawing Please refer to the specific product datasheet on www aeg industrialsolar de for the latest technical data 2 SAFETY 2 1 General safety All AEG PV modules should be installed according to all local and national applicable standards codes and regulations Only qualified personnel should install the solar modules Installers bear the risk of all injury that mi...

Страница 4: ...er metallic devices while installing or troubleshooting photovoltaic systems in order to avoid electric shock Do not disconnect modules under load to avoid electrical arcs Contact with electrically active parts of the modules such as terminals can result in burns sparks and lethal shock whether or not the module is connected Do not insert electrically conductive parts into the plugs and sockets Do...

Страница 5: ...ce of the modules to sea water or lakes should therefore be at least 500 mt unless otherwise specified The module should not be exposed to unusual chemical loads For fire safety indications please see 2 4 Fire safety Protect the solar modules from overvoltage e g voltage peaks of battery charges generators etc If the module has to be connected to a storage battery all precautions as prescribed by ...

Страница 6: ...lting pressure clamps See 3 2 2 Clamping 3 2 1 Bolting Always observe the instructions and safety precautions of the mounting system Modules must be securely fixed to the mounting system support rails using the provided mounting holes There are 4 four mounting holes placed to optimize the load handling capability of the module and to secure it to the supporting structure If increased wind or snow ...

Страница 7: ... Pa Allowed assembly with clamp 0 H 1 4W Allowed assembly with clamp 0 H 1 4W Figure 6 Clamping Loading capacity scheme Mounting by insertion Load positive 1600Pa negative 1600 Pa Load positive 5400 Pa negative 2400 Pa Allowed assembly with clamp 1 2L 50 S 1 2L 50 Figure 7 Insertion Loading capacity scheme 3 3 Electrical Installation and Grounding 3 3 1 General remarks Modules electrically connect...

Страница 8: ...ironmental conditions Always ensure that the modules are assembled with the appropriate string fuse for circuit protection based on the maximum series fuse rating of the module and local electrical installation codes There is no specific limitation on the number of modules that can be connected in parallel the number of modules is determined by system design parameters such as current or power out...

Страница 9: ...ing maintenance Follow the maintenance instructions for all components used in the system such as support frames charge regulators inverters batteries etc 4 2 Cleaning Do not clean modules with broken glass or exposed wiring This can cause a general electrical failure of the module or electrical shock hazard Dirt and dust can accumulate on the glass surface of the PV module over time particularly ...

Страница 10: ...ation use and maintenance of the product are beyond Solar Solutions s control Solar Solutions expressly disclaims liability for loss damage or expense arising out of or in any way connected with such installation operation use or maintenance No responsibility is assumed by Solar Solutions GmbH for any infringement of patents or other rights of third parties which may result from use of the PV prod...

Отзывы: