MD 0 – Continuous reading mode
The reader tries continuously to power up a transponder and to read it’s code. External triggering is not nec-
essary.
Figure 13: Continuous reading process
This operation mode can be configured with the following commands:
MD 0 – Continuous reading
CID X - Setting of the equal ID code suppression.
CID 0 Equal ID codes are read several times.
CID 1 Suppression of equal ID codes.
CN X - Setting of the no read message output.
CN 0
No suppression of no read messages.
CN 1
Suppression of no read messages.
NID X
Additional error protection. Internal comparison of the transponder.
NID 0 - 1 out of 1 selection
NID 1 2 out of 2 selection