VER – Software version of the reader
The command VER asks the reader for its software version.
Input format:
VER <CR>
Output:
i5_XXXXX <CR>
e.g. i5_MTR09 <CR>
MD – Operation mode
The operation mode of the reader is changed with the command MD.
Input format:
MD <SP> <Parameter> <CR>
Parameter:
Parameter
Function
0
Continuous reading mode
2
Command mode
Output (e.g.):
2 <CR>
Note:
In software version MTR15 MD parameter is not saved.
The reader is starting in command mode. If it is changed
to continuous reading mode the reader does not respond to
commands any longer. It is exclusively sending
transponder codes or no read messages. To switch it back
to command mode it has to be restarted.
GT – Reading command get tag
The command GT starts a reading attempt. See chapter “Operation modes” “MD 2 – Command mode”.
Input format:
GT <CR>
Output (Example):
Depending on the parameter settings and the read transponder signal there are
three different answers possible:
•
Transponder number, e.g. 001F37BD92 <CR>
•
No read message, XXXXXXXXXX <CR>
•
<CR> as a command acknowledgement, if a filter function is active, that
suppresses transponder code or the no read message.