CD – Code presentation
The code presentation of a ISO transponder can be changed by changing the CD parameter:
Input format:
CD <SP> Parameter <CR>
Parameter:
Parameter
Function
0
Hexadecimal e.g. 145A1000004F0001
1
ISO animal e.g. 968 000000547368
2
ISO industry
3
ISO BDE
Output (Example):
2 <CR>
Operation modes
Two operation modes are defined:
•
Operation mode 0 – Command mode
•
Operation mode 2 – Continuous reading mode
In the following chapters their functionality is described.
MD 2 – Command mode
The communication partner is sending the command „Get tag“ („GT<CR>“) to start a reading attempt. The
result, the transponder code or a no read message, is sent back.
In operation mode 2 the exciter is normally switched off. Triggered by the GT command input the exciter is
activated. When the reading cycle is finished, it is switched off again.
Figure 11: Software triggered reading mode