14
Installation - for contractors
12.
Recommissioning
See chapter „Commissioning“.
13.
Appliance handover
» Explain the appliance function to users and familiar-
ise them with its operation.
» Make users aware of potential dangers, especially
the risk of scalding.
» Hand over these instructions.
14.
Troubleshooting
Fault
Cause
Remedy
The appliance fails to
deliver hot water.
There is no power.
Check the fuse/MCB
in your fuse box/distri-
bution panel.
The high limit safety
cut-out has respond-
ed.
Remedy the cause of
the fault. Reset the
high limit safety cut-
out by pressing its
reset button.
Water can only be
drawn at a reduced
rate.
The jet controller in
the tap is scaled up.
Descale or replace the
jet controller.
Loud boiling noises in-
side the appliance.
The appliance is
scaled up.
Descale the appli-
ance.
Resetting the high limit safety cut-out
26
_0
2_0
6_0
19
2
15.
Maintenance
Risk to life through electrocution!
Before any work on the appliance, disconnect all
poles from the power supply.
» Dismount the appliance for maintenance work.
15.1
Draining the appliance
Drain the appliance via the connector.
15.2
Opening the appliance
26
_0
2_0
6_0
19
1
»
Remove the five screws from the appliance cap.
» Pull off the controller button.
» Remove the screw underneath the controller button.
» Remove the appliance cap.
15.3
Removing the thermal insulation
» Remove the earth strap from the cylinder.
» Release the tie.
» Remove the upper insulation semi-shell.
15.4
Removing the flanged immersion
heater and protective anode
26
_0
2_0
6_0
19
3
15.5
Fitting the protective anode
» To include the steel cylinder in the equipotential
bonding, keep the fixing elements in the same order
when fitting the protective anode; see chapter „Re
-
moving the flanged immersion heater and protective
anode“.