AE Conversion INV315-50EU Скачать руководство пользователя страница 5

5

11.2019

INV315-50EU

  Observe special disposal! 

Under „Observe special disposal“ it is pointed 
out that this product must not be disposed of 
with normal waste. Improper disposal may cause 
damage to the environment.

3.0 Notes on liability, warranty and service

The following information relates to liability, warranty and 
service.

3.1 Intended use and liability

The AEconversion PV inverter converts the DC voltage generated 
by PV modules into AC voltage and feeds this into the grid. Any 
other use or use that goes beyond this is considered improper 
use. The manufacturer/supplier is not liable for any damage 
resulting from this. The risk is borne solely by the operator.  
       
Intended use also includes observing the operating and 
installation instructions. Some of the documents you need for 
the registration and acceptance of your photovoltaic system are 
attached to the installation instructions. 
 
 

The inverter may only be operated with a fixed connection to 
the public grid. The inverter is not intended for mobile use. 
Modifications to the inverter are generally prohibited. For 
changes in the environment, you must always consult a qualified 
electrician.

3.2 Guaranty and Warranty

AEconversion grants a statutory warranty of 10 years from the 
date of purchase on the inverters. In addition, AEconversion 
grants a further multi-year limited warranty. 
If you have any questions about the warranty, please contact 
your specialist dealer or installer. If your device has a defect or 
malfunction during the warranty period, please also contact 
your specialist dealer or installer. 

Warranty claims are excluded in the event of:

• 

Unauthorised modifications to the unit or repair attempts

• 

Opening the inverter, for example by unscrewing the cover

• 

Non-intended use of the units

• 

 Improper installation that does not comply with the standards

• 

Improper operation

• 

 Operating the units with defective protective devices

• 

 Impact of foreign bodies and force majeure (lightning, 
overvoltage, thunderstorms, fire)

• 

Insufficient or non-existent ventilation of the unit

• 

Non-observance of safety regulations

• 

 Transport  damage

• 

Use of non-original PV mating plugs and sockets from the 
HELIOS H4 product series by Amphenol 

 

 

 

  - The installation must only be carried out by 

persons who have a recognized professional 
qualification as electricians. 
- If you mount the inverters at a great height, avoid 
possible risks of falling. 
- Do not insert any electrically conductive parts 
into the plugs and sockets!  Tools must be dry. 

  - The electrical connection to the central building 

services may only be carried out by a licensed 
electrician.

  - Do not tamper with or manipulate the inverter or 

other parts of the system under any circumstances.  
- Risk of damage due to improper modifications! 

2.2 CE Mark

The CE mark documents that the inverter fulfills the basic 
requirements of the following relevant directives according to 
the type plate:

• 

Electromagnetic  Compatibility 

   

2014/30/EU                                        

Low 

Voltage 

Directive 

  2014/35/EU

For CE declaration of conformity, see page 17.

2.3 Label

The label is located on the top or on the side edge of the 
inverter. The information on the label includes the technical data 
as well as the article and serial number of the device. 
Safety instructions on the type plate are listed and explained 
below: 

  Danger!  „

Danger“ indicates a situation which, if 

not avoided, will result in personal injury.

  Attention!   „Attention“ indicates a situation which, 

if not avoided, may result in damage to property.

  Observe operating instructions! 

Under „Observe operating instructions“ it 
is pointed out that assembly and operating 
instructions must be read and understood before 
assembly, installation and maintenance.

  Caution hot surface! 

Under „Caution hot surface“ it is pointed out that 
surfaces of devices could be hot and there is a risk 
of burns.

Содержание INV315-50EU

Страница 1: ...Micro Inverter English INV315 50EU ...

Страница 2: ...Assembly and operating instructions INV315 50EU Printed in Germany Copyright by AEconversion GmbH Co KG ...

Страница 3: ...Protection concepts 7 5 5 Network and system protection 7 6 0 Operating conditions 8 6 1 Dimensioning of the PV generator 8 7 0 Installation 8 7 1 Installation on PV racking 9 7 2 Mounting alternatives 9 8 0 Connections 9 8 1 Overview of connections 10 8 1 1 Connection areas of the inverter 10 8 2 AC Connection 10 8 1 2 AC Connection of many devices 11 8 3 DC Connection 11 8 4 Communication setup ...

Страница 4: ...tions of all parts and components of the system 2 1 General information and safety instructions The proper and safe operation of this device requires proper transport storage installation and assembly as well as careful operation and maintenance When operating this equipment certain parts of the equipment are under dangerous voltage which can cause serious bodily injury or death Therefore please f...

Страница 5: ...es not comply with the standards Improper operation Operating the units with defective protective devices Impact of foreign bodies and force majeure lightning overvoltage thunderstorms fire Insufficient or non existent ventilation of the unit Non observance of safety regulations Transport damage Use of non original PV mating plugs and sockets from the HELIOS H4 product series by Amphenol The insta...

Страница 6: ...signed for operating temperatures from 25 C to 70 C If the temperature inside the enclosure exceeds a certain value the inverter automatically regulates the maximum power to protect itself Systems with micro inverters are easy to design and install Each inverter can be mounted on the mounting rack underneath the PV modules but it is recommended to have a place where emergency service work can be e...

Страница 7: ...75sec OFF 0 25sec 1 cycle AC voltage not within tolerance range LED 1sec ON 0 75sec OFF 0 25sec 2 cycles DC voltage not within tolerance range LED 1sec ON 0 75sec OFF 0 25sec 3 cycles AC and DC voltages not within tolerance range LED 1sec ON 0 75sec OFF 0 25sec 4 cycles Internal overtemperature LED 1sec ON 0 75sec OFF 0 25sec 5 cycles Sequence ends 2 sec AUS Insulation measurement on the PV side I...

Страница 8: ... a 24V module The open circuit voltage of the entire PV generator must be less than 50 for INV315 UMpp 60 C input voltage 20 VDC for INV315 50EU The UMpp voltage of the connected string should not fall below the permitted input voltage range even at very high module temperatures 60 C If the temperature rises from 25 C to 60 C the UMpp voltage of 12 V modules drops by approx by approx 3 6 V per mod...

Страница 9: ...e help of accessories that are matched to the mounting frame As an example slot stones can be fastened to the mounting profiles at the positions below the inverter brackets with screws When mounting make sure that the inverter is mounted in the correct installation position the cover must face upwards connection plugs must point downwards 7 2 Installation alternative If mounting on the mounting fr...

Страница 10: ...reases during feed in operation This voltage is measured by the inverter If the voltage at the grid terminals exceeds the limit for grid overvoltage the inverter switches off due to grid overvoltage This circumstance must be taken into account in the AC wiring and when dimensioning the AC line When using several AC circuits in a PV system it is necessary to distribute the feed in phase symmetrical...

Страница 11: ...nnection before connecting it to the inverter Only use original mating plugs and sockets from the HELIOS H4 product range from Amphenol Observe the Amphenol assembly instructions for the DC connectors if you assemble the cables yourself Check that the PV generator is free of earth faults before connecting it to the inverter Before connecting the DC cables to the inverter check whether the maximum ...

Страница 12: ...of the inverter different procedures must be followed Please follow the communication setup procedure that is appropriate for your inverter 8 4 1 RF Communication If the micro inverter is equipped with RF communication the steps for setting up communication including wiring and monitoring are described below Communication via the RFC interface takes place via a frequency of 2 4 GHz In combination ...

Страница 13: ...e short circuit resistance of the switching devices 10 0 Switching off the inverter You must switch off the inverter for adjustment maintenance and repair work Proceed as follows Switch off the mains voltage deactivate the external fuse elements After switching off check that there is no voltage Follow the local regulations for work on electrical installations Danger to life due to electric shock ...

Страница 14: ... dirt 12 3 Laws regulations and technical rules When constructing solar installations the laws and regulations applicable to the respective country at state federal and European or international level must be observed In general the generally recognised rules of technology apply which are usually formulated in the form of standards guidelines regulations provisions and technical rules by state and...

Страница 15: ...ncy 96 European efficiency 95 MPPT efficiency 99 8 Mechanical Data Operating Temperature 25 C 70 C Night time power consumption 30 mW Max altitude a s l 2000 m DC Input Amphenol H4 AC Output female connector Wieland system RSTi mini Dimensions WxHxD 390mm x 100 mm x 30 mm Weight 0 8 kg Cooling natural convection Enclosure material aluminum Protection Degree IP65 iP67 NEMA4 50 Hz Version Nominal AC...

Страница 16: ...v T ambient 0m s P pv 30V P pv 35V P pv 40V P pv 25V 100 W 150 W 200 W 250 W 300 W 15 C 10 C 5 C 0 C 5 C 10 C 15 C 20 C 25 C 30 C PV input power T amb 0 1m s wind speed Derating diagramm Ppv T ambient 0 1 m s P pv 30V P pv 25V P pv 40V Derating diagrams for INV315 6 0 A 6 5 A 7 0 A 7 5 A 8 0 A 8 5 A 9 0 A 9 5 A 10 0 A 250 W 260 W 270 W 280 W 290 W 300 W 310 W 320 W 26 V 28 V 30 V 32 V 34 V 36 V 38...

Страница 17: ...mmen mit den Vorschriften folgender europäischer Richtlinien überein The indicated products are in correspondence with the following regulations of European Council Nummer Kurztitel Number Titel Eingehaltene Vorschriften Observed regulations 2014 30 EU EMV Richtlinie EMC Directive EN 61000 6 2 2005 EN 61000 6 3 2007 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 2014 35 EU Niederspannungsrich...

Страница 18: ...al 12 TR Turkey 13 LT Lithuania 14 LV Latvia 15 BG Bulgaria 16 CY Cyprus 17 SE Sweden 18 CH Switzerland 19 PL Poland 20 CZ Czech Republic 21 SK Slowakia 22 FI Finnland 23 AL Albany 24 IE Ireland 25 SI Slovenia 26 MT Malta 27 HR Croatia 28 RO Romania 29 XZ Kosovo 40 IL Israel 41 AU Australia 42 TN Tunisia 43 BB Barbados 44 CL Chile 45 ZA South Africa 46 IR Iran 47 CN China 48 KZ Kazakhstan 49 IN In...

Страница 19: ...19 11 2019 INV315 50EU AEconversion GmbH Co KG An der Helle 26 59505 Bad Sassendorf Germany Telefon 49 0 2927 9194 10 Telefax 49 0 2927 9194 50 www aeconversion de ...