background image

 

to the controller. 

 
4. Connect positive terminal (+) of battery to the battery positive terminal (+) on the 
controller.   
5. Connect negative terminal (-) of battery to one of the Common Negative terminals (-) 
on the controller. 

 

WARNING: Risk of Damage 

Be sure that solar connection is made with correct polarity. Turn on the solar 

breaker/disconnect and measure the voltage on the open wires BEFORE connecting to the 

controller. Disconnect solar breaker/disconnect before wiring to the controller. 

 

6. Connect positive wire (+) of solar module to the solar positive terminal (+) on the 
controller.   
7. Connect negative wire (-) of solar module to one of the Common Negative terminals 
(-) on the controller. 
8. Screw four (4) power terminals tightly with 50 in-lbs torque. (5.65 Nm) 

 

3.5 Grounding and Ground Fault Interruption 

Use a copper wire to connect the grounding terminal in the wiring box to earth ground. 
The  grounding  terminal  is  identified  by  the  ground  symbol  shown  below  that  is 
stamped into the wiring box just below the terminal: 

 

The minimum size of the copper grounding wire is 8 AWG (10 mm2). 

WARNING: Risk of Fire 

DO NOT bond system electrical negative to earth ground at the controller. 

 

3.6 Remote Temperature Sensor   

The  included  Remote  Temperature  Sensor  (RTS)  is  recommended  for  effective 
temperature  compensated  charging.  Connect  the  RTS  to  the  2-pole  terminal  (see 
figure as below).

 

The RTS is supplied with 33 ft (10 m) of 22 AWG (0.34 mm2) cable. 

There is no polarity, so either wire (+ or -) can be connected to either screw terminal. 

www.

ADVICE

.co.il

e-mail:advice@advice.

co.il

Содержание ASC-MPPT-3000

Страница 1: ...1 Solar Charge Controller 3KW User Manual www ADVICE co il e mail advice advice co il...

Страница 2: ...3 3 Mounting the Unit 6 3 4 Power Connection 7 3 5 Grounding and Ground Fault Interruption 9 3 6 Remote Temperature Sensor 9 3 7 Battery Voltage Sense 10 3 8 Communication Connections 11 4 OPERATION...

Страница 3: ...reduce this risk 4 CAUTION Only qualified personnel can install this device with battery 5 NEVER charge a frozen battery 6 For optimum operation of this charger please follow required spec to select...

Страница 4: ...errors or system faults occur This charger also features multifunctional LCD with communication ports for remote battery temperature and voltage measurement 2 1 Features Intelligent Maximum Power Poin...

Страница 5: ...ndicator 4 Wiring fault indicator 5 Operation button 6 PV connectors 7 Battery connectors 8 Battery voltage sense terminal 9 Remote temperature sensor terminal 10 Wiring box cover 11 Communication por...

Страница 6: ...oints before selecting where to install This solar charge controller is designed in IP31 for indoor applications only Do not mount the unit on flammable construction materials Mount on a solid surface...

Страница 7: ...ize Typical Amperage Wire Type 75 C Wire 90 C Wire 60A Copper 4 AWG 25 mm2 6 AWG 16 mm2 Aluminum 2 AWG 35 mm2 4 AWG 25 mm2 Overcurrent Protection and Disconnects CAUTION Circuit breakers or fuses must...

Страница 8: ...ches inside the charger 2 Make 4 power wires first Remove insulation sleeve 10 5mm and the conductor should be plated Tin Refer to the chart below 3 Pull all wires into the wiring box The Remote Tempe...

Страница 9: ...Screw four 4 power terminals tightly with 50 in lbs torque 5 65 Nm 3 5 Grounding and Ground Fault Interruption Use a copper wire to connect the grounding terminal in the wiring box to earth ground The...

Страница 10: ...connection on the controller may differ slightly from the voltage directly at the battery bank terminals due to connection and cable resistance The Battery Voltage Sense connection enables the contro...

Страница 11: ...wires may be pulled through conduit with the power conductors Tighten the connector screws with 5 in lb 0 56 Nm torque The maximum length allowed for each battery voltage sense wire is 98 ft 30 m 3 8...

Страница 12: ...ware CD into a computer and follow on screen instruction to install the monitoring software For the detailed software operation please check user manual of software inside of CD www ADVICE co il e mai...

Страница 13: ...en it will indicate a successful start up in LCD display Turn on solar disconnect switch If the solar module is in full sunlight the controller will begin charging 4 2 Operation and Display Panel The...

Страница 14: ...s it will automatically save current setting and exit the setting mode Backlight on Press shortly 4 2 LCD Display Icons Icon Function description Input Source Information Indicates the PV input voltag...

Страница 15: ...de Constant Voltage mode 2V cell 4 bars will flash in turns 2 2 083V cell The right bar will be on and the other three bars will flash in turns 2 083 2 167V cell The two right bars will be on and the...

Страница 16: ...g mode All current setting will be saved automatically Refer to below chart for set up charging current 4 4 Reference Code Type Code Event Fault 01 Over charge current 02 Over temperature 03 Battery v...

Страница 17: ...em remains please contact your installer 05 PV high loss 1 Please check the voltage of the solar panel it should be less than 140V 2 If the voltage is ok please contact your installer 06 Battery tempe...

Страница 18: ...tion 4500 Watts port Protections Solar high voltage disconnect Solar high voltage reconnect Battery high voltage disconnect Battery high voltage reconnect High temperature disconnect High temperature...

Страница 19: ...tage 14 5V 29V 58V Battery defect voltage 8 5V 17V 34V Battery defect comeback voltage 9V 18V 36V Charging Curve Table 3 Mechanical and Environment Charger MODEL MPPT 3K Product size W x H x D mm 315...

Отзывы: