16
4.3 Charging Current Setting
After pressing and holding the button for 5 seconds, the unit will enter setting mode.
Only charging current is able to set up. Press button shortly to switch setting current
figure from C1 to C6, presenting 10A to 60A. After retaining in setting figure and
nothing to press for 5 second, it will exit setting mode. All current setting will be saved
automatically. Refer to below chart for set up charging current.
4.4 Reference Code
Type
Code
Event
Fault
01
Over charge current
02
Over temperature
03
Battery voltage is too low
04
Battery voltage is high
05
PV is high loss
06
Battery temperature is too low
07
Battery temperature is too high
Warning
20
PV is low loss
21
Output derating caused from high PV voltage
22
Output derating caused from high temperature
23
Low alarm for battery temperature