1.3 SAFETY INSTRUCTIONS 

WARNING:  This  chapter  contains  important  safety  and  operating 

instructions. Read and keep this manual for future reference. 

1.

 

Before using the unit, read all instructions and cautionary markings on the unit, 
the batteries and all appropriate sections of this manual.   

2.

 

Do not disassemble the unit. Take it to a qualified service center when service 
or repair is required. Incorrect re-assembly may result in a risk of electric shock 
or fire. 

3.

 

To reduce risk of electric shock, disconnect all wirings before attempting any 
maintenance or cleaning. Turning off the unit will not reduce this risk.   

4.

 

CAUTION 

– Only qualified personnel can install this device with battery.   

5.

 

NEVER 

charge a frozen battery. 

6.

 

For optimum operation of this charger, please follow required spec to select 
appropriate cable size. It’s very important to correctly operate this charger. 

7.

 

Be  very  cautious  when  working  with  metal  tools  on  or  around  batteries.  A 
potential risk exists to drop a tool to spark or short circuit batteries or other 
electrical parts and could cause an explosion.   

8.

 

Please strictly follow installation procedure when you want to disconnect PV or 
battery terminals. Please refer to INSTALLATION section of this manual for the 
details. 

9.

 

GROUNDING  INSTRUCTIONS  -This  charger  should  be  connected  to  a 
permanent grounded wiring system. Be sure to comply with local requirements 
and regulation to install this charger. 

10.

 

NEVER cause short circuited on battery output.   

11.

 

Warning!! 

Only qualified service persons are able to service this device. If 

errors still persist after following troubleshooting table, please send this 
charger back to local dealer or service center for maintenance. 

 

www.

ADVICE

.co.il

e-mail:advice@advice.

co.il

Содержание ASC-MPPT-3000

Страница 1: ...1 Solar Charge Controller 3KW User Manual www ADVICE co il e mail advice advice co il...

Страница 2: ...3 3 Mounting the Unit 6 3 4 Power Connection 7 3 5 Grounding and Ground Fault Interruption 9 3 6 Remote Temperature Sensor 9 3 7 Battery Voltage Sense 10 3 8 Communication Connections 11 4 OPERATION...

Страница 3: ...reduce this risk 4 CAUTION Only qualified personnel can install this device with battery 5 NEVER charge a frozen battery 6 For optimum operation of this charger please follow required spec to select...

Страница 4: ...errors or system faults occur This charger also features multifunctional LCD with communication ports for remote battery temperature and voltage measurement 2 1 Features Intelligent Maximum Power Poin...

Страница 5: ...ndicator 4 Wiring fault indicator 5 Operation button 6 PV connectors 7 Battery connectors 8 Battery voltage sense terminal 9 Remote temperature sensor terminal 10 Wiring box cover 11 Communication por...

Страница 6: ...oints before selecting where to install This solar charge controller is designed in IP31 for indoor applications only Do not mount the unit on flammable construction materials Mount on a solid surface...

Страница 7: ...ize Typical Amperage Wire Type 75 C Wire 90 C Wire 60A Copper 4 AWG 25 mm2 6 AWG 16 mm2 Aluminum 2 AWG 35 mm2 4 AWG 25 mm2 Overcurrent Protection and Disconnects CAUTION Circuit breakers or fuses must...

Страница 8: ...ches inside the charger 2 Make 4 power wires first Remove insulation sleeve 10 5mm and the conductor should be plated Tin Refer to the chart below 3 Pull all wires into the wiring box The Remote Tempe...

Страница 9: ...Screw four 4 power terminals tightly with 50 in lbs torque 5 65 Nm 3 5 Grounding and Ground Fault Interruption Use a copper wire to connect the grounding terminal in the wiring box to earth ground The...

Страница 10: ...connection on the controller may differ slightly from the voltage directly at the battery bank terminals due to connection and cable resistance The Battery Voltage Sense connection enables the contro...

Страница 11: ...wires may be pulled through conduit with the power conductors Tighten the connector screws with 5 in lb 0 56 Nm torque The maximum length allowed for each battery voltage sense wire is 98 ft 30 m 3 8...

Страница 12: ...ware CD into a computer and follow on screen instruction to install the monitoring software For the detailed software operation please check user manual of software inside of CD www ADVICE co il e mai...

Страница 13: ...en it will indicate a successful start up in LCD display Turn on solar disconnect switch If the solar module is in full sunlight the controller will begin charging 4 2 Operation and Display Panel The...

Страница 14: ...s it will automatically save current setting and exit the setting mode Backlight on Press shortly 4 2 LCD Display Icons Icon Function description Input Source Information Indicates the PV input voltag...

Страница 15: ...de Constant Voltage mode 2V cell 4 bars will flash in turns 2 2 083V cell The right bar will be on and the other three bars will flash in turns 2 083 2 167V cell The two right bars will be on and the...

Страница 16: ...g mode All current setting will be saved automatically Refer to below chart for set up charging current 4 4 Reference Code Type Code Event Fault 01 Over charge current 02 Over temperature 03 Battery v...

Страница 17: ...em remains please contact your installer 05 PV high loss 1 Please check the voltage of the solar panel it should be less than 140V 2 If the voltage is ok please contact your installer 06 Battery tempe...

Страница 18: ...tion 4500 Watts port Protections Solar high voltage disconnect Solar high voltage reconnect Battery high voltage disconnect Battery high voltage reconnect High temperature disconnect High temperature...

Страница 19: ...tage 14 5V 29V 58V Battery defect voltage 8 5V 17V 34V Battery defect comeback voltage 9V 18V 36V Charging Curve Table 3 Mechanical and Environment Charger MODEL MPPT 3K Product size W x H x D mm 315...

Отзывы: