Advatek Lights PIXLITE 4 RUGGED Скачать руководство пользователя страница 9

 

 
 
 
 
 
 
PixLite 4 Rugged V1.0 User Manual V1.2 

 

© 2015 Advatek Lighting Pty Ltd 

 

3.2 

 IP Addressing 

3.2.1 - Using a Router 
 

Routers have a DHCP server in them 

 this means they will tell a device plugged into them what IP 

address to use, if asked. 

DHCP is always enabled by default on a PixLite controller so it can immediately connect to any 
existing network with a router. However it is recommended that you assign a static IP address once 
communications have been established via the Advatek Assistant. If the controller is in DHCP mode 
and is not assigned an IP address by a DHCP server, it will timeout after 15 seconds and default to a 
static IP of 192.168.0.50 

If DHCP mode is enabled, both status and power LEDs will flash together until the controller receives 
an IP address, at which point the power LED will remain on solid and the status LED will flash slowly 
indicating it is in run mode and ready for use. 

If a static IP address is assigned to the board, then the power LED will be solid from power up. If a 
DHCP timeout occurs the power LED will stop flashing and go solid also. 

3.2.2 - Using A Switch/Direct 
 

It may be desirable to connect the controller directly to a switch or even directly to the host machine 
instead of using a router. In this case (for first time configuration) you will need to ensure that the 
network adapter of your computer is set in the IP range that the controller will default to (controller 

defaults to 192.168.0.50). This means you PC’s IP should be 192.168.0.xxx where xxx is anything 

between 1 and 254 other than 50. The subnet mask on your PC should be set to 255.255.255.0.  

Once you can successfully discover the controller in the Assistant, we recommended setting the 
controller to a static IP address other than the default. 

Figure 5 shows a screenshot of typical computer network settings to communicate with a PixLite 4 
Rugged controller for the first time without a router. 

Содержание PIXLITE 4 RUGGED

Страница 1: ...PIXLITE 4 RUGGED CONTROLLER HARDWARE REV 1 0 USER MANUAL V1 2...

Страница 2: ...a Router 8 3 2 2 Using A Switch Direct 8 3 2 3 Forcing the Default IP Address 9 4 Operation 10 4 1 Startup 10 4 2 Sending Data 10 4 3 Outputs 10 4 4 Hardware Test Pattern 10 5 Firmware Upgrades 11 5...

Страница 3: ...2 PixLite 4 Rugged V1 0 User Manual V1 2 2015 Advatek Lighting Pty Ltd 7 4 Reset To Factory Defaults 15 8 Warranty and Service 16...

Страница 4: ...rated plug and play outdoor pixel solution quickly and with a minimum of effort The PixLite 4 Rugged controller converts the E1 31 sACN and Art net protocols from a lighting console media server or co...

Страница 5: ...ower supply if desired If using your own power supply the input voltage can be anywhere between 5V and 12V DC and it is the user s responsibility to ensure that the power supply used matches the volta...

Страница 6: ...use any value of fuse up to and including 7 5A depending on your specific application Individual outputs should not exceed 7 5A and the total current should not exceed 30A If you require more current...

Страница 7: ...vatek pixel strings and pixel tape are designed to plug straight into the controller via the 4 pin male screw up connectors labelled OUTPUT 1 to OUTPUT 4 If using your own pixels with our mating pigta...

Страница 8: ...Ethernet cables If you are only using a few controllers they can be connected straight to the router Larger installations will benefit from using a network switch between the router and controllers Us...

Страница 9: ...owly indicating it is in run mode and ready for use If a static IP address is assigned to the board then the power LED will be solid from power up If a DHCP timeout occurs the power LED will stop flas...

Страница 10: ...e IP of a controller and you can t see it in the Assistant it can be forced to its default IP After removing the enclosure lid a simple procedure can be employed on power up 1 Hold down the Factory IP...

Страница 11: ...4 outputs can drive up to 680 individual pixels Each individual output is rated at 7 5A The refresh rate of the pixels will depend on the operating frequency of the specific pixel type Typically it c...

Страница 12: ...ming an Automatic Update 1 Open the Assistant Click Search and once the desired controller appears in the main window double click on it 2 A configuration window will appear Click on the Misc tab and...

Страница 13: ...so you must ensure you are running it on a network in the same address range as this IP address E G 192 168 0 10 3 Using the Assistant click search in the main window and you should see the controlle...

Страница 14: ...oltage 5 12 V DC Max Current Capacity 30 A Logic Current Consumption 5V DC 130 mA Recommended Ambient Temperature1 20 to 50 C PCB Component Absolute Maximum Temperature 40 to 80 C Max Current Per Outp...

Страница 15: ...SLOW FLASHING TEST MODE RUNNING FLASHING TOGETHER FLASHING TOGETHER LOOKING FOR IP ADDRESS DHCP MODE SOLID SOLID MAIN APPLICATION NOT RUNNING SOLID OFF MAIN APPLICATION NOT RUNNING OFF SOLID MAIN APPL...

Страница 16: ...nline knowledgebase here http www advateklights com support kb If you can t resolve your problem with the help of our knowledgebase you can open a support ticket here for assistance http www advatekli...

Страница 17: ...warranty cases the support staff will usually require you to perform some troubleshooting steps first If we cannot solve your problem remotely we will issue you with an RMA number through the support...

Отзывы: