2.2 - Output Fuses 

 

Each individual output is protected by a mini blade fuse. You may use any value of fuse, up to and 
including 7.5A, depending on your specific application. Individual outputs should not exceed 7.5A 
and the total current should not exceed 30A. If you require more current than this, then you will 
need to inject power into the pixels directly off board. 

 
 

 

Figure 3 

 

 

Bootloader 
 

Factory IP 
 

4 x Mini Blade Fuses 
 

Status LED 
 

Power LED 
 

Содержание PIXLITE 4 RUGGED

Страница 1: ...PIXLITE 4 RUGGED CONTROLLER HARDWARE REV 1 0 USER MANUAL V1 2...

Страница 2: ...a Router 8 3 2 2 Using A Switch Direct 8 3 2 3 Forcing the Default IP Address 9 4 Operation 10 4 1 Startup 10 4 2 Sending Data 10 4 3 Outputs 10 4 4 Hardware Test Pattern 10 5 Firmware Upgrades 11 5...

Страница 3: ...2 PixLite 4 Rugged V1 0 User Manual V1 2 2015 Advatek Lighting Pty Ltd 7 4 Reset To Factory Defaults 15 8 Warranty and Service 16...

Страница 4: ...rated plug and play outdoor pixel solution quickly and with a minimum of effort The PixLite 4 Rugged controller converts the E1 31 sACN and Art net protocols from a lighting console media server or co...

Страница 5: ...ower supply if desired If using your own power supply the input voltage can be anywhere between 5V and 12V DC and it is the user s responsibility to ensure that the power supply used matches the volta...

Страница 6: ...use any value of fuse up to and including 7 5A depending on your specific application Individual outputs should not exceed 7 5A and the total current should not exceed 30A If you require more current...

Страница 7: ...vatek pixel strings and pixel tape are designed to plug straight into the controller via the 4 pin male screw up connectors labelled OUTPUT 1 to OUTPUT 4 If using your own pixels with our mating pigta...

Страница 8: ...Ethernet cables If you are only using a few controllers they can be connected straight to the router Larger installations will benefit from using a network switch between the router and controllers Us...

Страница 9: ...owly indicating it is in run mode and ready for use If a static IP address is assigned to the board then the power LED will be solid from power up If a DHCP timeout occurs the power LED will stop flas...

Страница 10: ...e IP of a controller and you can t see it in the Assistant it can be forced to its default IP After removing the enclosure lid a simple procedure can be employed on power up 1 Hold down the Factory IP...

Страница 11: ...4 outputs can drive up to 680 individual pixels Each individual output is rated at 7 5A The refresh rate of the pixels will depend on the operating frequency of the specific pixel type Typically it c...

Страница 12: ...ming an Automatic Update 1 Open the Assistant Click Search and once the desired controller appears in the main window double click on it 2 A configuration window will appear Click on the Misc tab and...

Страница 13: ...so you must ensure you are running it on a network in the same address range as this IP address E G 192 168 0 10 3 Using the Assistant click search in the main window and you should see the controlle...

Страница 14: ...oltage 5 12 V DC Max Current Capacity 30 A Logic Current Consumption 5V DC 130 mA Recommended Ambient Temperature1 20 to 50 C PCB Component Absolute Maximum Temperature 40 to 80 C Max Current Per Outp...

Страница 15: ...SLOW FLASHING TEST MODE RUNNING FLASHING TOGETHER FLASHING TOGETHER LOOKING FOR IP ADDRESS DHCP MODE SOLID SOLID MAIN APPLICATION NOT RUNNING SOLID OFF MAIN APPLICATION NOT RUNNING OFF SOLID MAIN APPL...

Страница 16: ...nline knowledgebase here http www advateklights com support kb If you can t resolve your problem with the help of our knowledgebase you can open a support ticket here for assistance http www advatekli...

Страница 17: ...warranty cases the support staff will usually require you to perform some troubleshooting steps first If we cannot solve your problem remotely we will issue you with an RMA number through the support...

Отзывы: