- 28 -
www.advateklights.com
PixLite T8-S Mk2 User Manual V211013
10 - Troubleshooting
Generally, troubleshooting requires looking at the LEDs on the front panel.
10.1 - LED Codes
Please refer to the table below for condition codes for the onboard status and power
LEDs.
Status LED (Red)
Power LED (Green)
Condition
Flashing
Solid
Normal operation,
Main application running okay
Slow flashing
Solid
Test mode running
Flashing together
Flashing together
Looking for IP address
(DHCP Mode)
Solid
Solid
Main application not running
Off
Solid
Main application not running
Solid
Off
Main application not running
Alternate flashing
Alternate flashing
Bootloader mode
Off
Off
No power
Please refer to the table below for condition codes for the Ethernet jack status LEDs.
Link LED (Green)
Data LED (Yellow)
Condition
Solid
Flashing
Connected okay, receiving data
Solid
Off
Connected okay, no data
Off
Off
No link established
10.2 - No Power/Status LEDs On
Ensure that the outlet you are plugged into is active.
If the lights are not turning on at all then double check all power connections and
fuses. The PixLite T8-S Mk2 has a fuse located in a recess inside the IEC socket at the
rear of the unit that may need to be replaced. See