- 15 -
www.advateklights.com
PixLite T8-S Mk2 User Manual V211013
5 - Electrical Connections
5.1 - Supplying Power
Power for the PixLite T8-S Mk2 controller is applied via the supplied AC power cable.
The controller is shipped with a 2m long IEC lead with a region specific power plug
which should be connected to the AC mains supply. The IEC input socket on the rear
of the enclosure, as shown in
below, also contains an accessible
compartment with 250V 1A glass fuse (F1A L 250V).
Figure 13: Location of Power Input
5.2 - Control Data
Ethernet data is connected via a standard network cable into the RJ45 Ethernet jack
located on the rear panel of the unit, as shown in
below. The controller
supports Streaming ACN (sACN / E1.31) or Art-Net data.
Figure 14: Position of Ethernet